2016
DOI: 10.4414/smf.2016.02820
|View full text |Cite
|
Sign up to set email alerts
|

Replik

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
3
0

Year Published

2018
2018
2018
2018

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 0 publications
1
3
0
Order By: Relevance
“…In most cases lead pipe behaved as the anode, consistent with empirical galvanic series (1,26,27). Occasionally, leaded brass or copper was found to behave as the anode instead of lead pipe (28,29), in which case the possibility for water lead contamination is minimized, because lead pipe behaves as the cathode and is protected from corrosion.…”
Section: Introductionsupporting
confidence: 68%
See 2 more Smart Citations
“…In most cases lead pipe behaved as the anode, consistent with empirical galvanic series (1,26,27). Occasionally, leaded brass or copper was found to behave as the anode instead of lead pipe (28,29), in which case the possibility for water lead contamination is minimized, because lead pipe behaves as the cathode and is protected from corrosion.…”
Section: Introductionsupporting
confidence: 68%
“…−2 ) were also quite variable when available, but data were fairly limited. As a result, the chloride-to-sulfate mass ratio (CSMR), a water quality factor deemed important in affecting galvanic corrosion (8,20,28,30,42) was not calculated herein. Meaningful calculations of the CSMR were not possible for several reasons: the chloride and sulfate concentrations were not available at Utility C; only single chloride/sulfate concentrations were available at Utilities D and E with no additional data on possible variability; and the chloride/sulfate data at remaining Utilities were not always paired.…”
Section: Drinking Water Qualitymentioning
confidence: 99%
See 1 more Smart Citation
“…For example, inductively coupled plasma mass spectrometry (ICP-MS) measurements have been commonly used to measure lead concentrations in many galvanic corrosion drinking water studies. (6)(7)(8)(9)(10) Although ICP-MS provides accurate and informative lead information, measurements are limited to bulk water lead concentrations. For a better understanding of galvanic corrosion, lead leaching and lead transport from metal surfaces as well as direct lead measurements at the interface, where corrosion occurs, are necessary.…”
Section: Introductionmentioning
confidence: 99%