2022
DOI: 10.4103/joco.joco_173_21
|View full text |Cite
|
Sign up to set email alerts
|

Repeatability of corneal densitometry measurements using a scheimpflug camera in healthy normal corneas

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 23 publications
2
4
0
Order By: Relevance
“…Furthermore, the repeatability of the measurement of the transparency in the middle layer of the cornea was better than that in the posterior and anterior layers of the cornea. These findings are in accord with the results of previous (intra-day) studies on cohorts of subjects with keratoconus 17 , 23 , and among healthy subjects 6 , 17 , 18 , 23 . However, to the best of our knowledge, no studies have been carried out to determine the inter-day repeatability of corneal densitometry measurements and thus, the results from this investigation cannot be compared.…”
Section: Discussionsupporting
confidence: 92%
See 2 more Smart Citations
“…Furthermore, the repeatability of the measurement of the transparency in the middle layer of the cornea was better than that in the posterior and anterior layers of the cornea. These findings are in accord with the results of previous (intra-day) studies on cohorts of subjects with keratoconus 17 , 23 , and among healthy subjects 6 , 17 , 18 , 23 . However, to the best of our knowledge, no studies have been carried out to determine the inter-day repeatability of corneal densitometry measurements and thus, the results from this investigation cannot be compared.…”
Section: Discussionsupporting
confidence: 92%
“…The findings of this study also show that measurements of the transparency of the middle 0–2 and 2–6-mm annular zones have better repeatability than the more outer zones (6–10 and 10–12 mm). The poorer repeatability in the more peripheral zones could be explained by the inclusion of the limbal and sceral area in the analysis, particularly in eyes with diameters less than 12 mm 18 . Another explanation could be that eyelids and lashes have a negative effect on the measurements.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…During the examination, the patient remains in a standardized dim-light condition for 5-10 min and is subjected to the test in the natural state of the pupil ( Pakbin et al, 2022 ). The patient, who is seated with their chin fixed on a mandibular brace, is asked to stare at a fixed target in the center of the Pentacam blue stripe without blinking or moving their eyes.…”
Section: Measurement Methods Of the Corneal Optical Densitymentioning
confidence: 99%
“…Scheimp ug cameras, such as the Pentacam (Oculus Optikgeraete GmbH; Wetzlar, Germany), have gained popularity as tools for assessing CD in healthy human eyes (4,(7)(8)(9)(10), and in various diseases, including diabetes mellitus (11), corneal infections (6), keratoconus (12), Fuchs endothelial dystrophy (13), refractive surgery (14,15), and keratoplasty (16,17).…”
Section: Introductionmentioning
confidence: 99%