Repeat transcatheter aortic valve implantation and implications for transcatheter heart valve performance: insights from bench testing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(9 citation statements)
references
References 20 publications
0
8
0
Order By: Relevance
“…Patient-prosthesis mismatch after a second TAVI, although less relevant than TAVI for degenerated surgical aortic valves, needs to be also anticipated: for example, a supra-annular TAV should be considered as the preferred strategy in case of degenerated intraannular TAV, particularly in case of small anatomies. 5 An emerging issue of redo TAVI procedure is the creation of a double stent layer that interposes between the aortic valve and coronary arteries. This barrier can create an obstacle to coronary reaccess and might even sequestrate the blood flow within the sinuses of Valsalva.…”
Section: See Article By Testa Et Almentioning
confidence: 99%
See 1 more Smart Citation
“…Patient-prosthesis mismatch after a second TAVI, although less relevant than TAVI for degenerated surgical aortic valves, needs to be also anticipated: for example, a supra-annular TAV should be considered as the preferred strategy in case of degenerated intraannular TAV, particularly in case of small anatomies. 5 An emerging issue of redo TAVI procedure is the creation of a double stent layer that interposes between the aortic valve and coronary arteries. This barrier can create an obstacle to coronary reaccess and might even sequestrate the blood flow within the sinuses of Valsalva.…”
Section: See Article By Testa Et Almentioning
confidence: 99%
“…Patient-prosthesis mismatch after a second TAVI, although less relevant than TAVI for degenerated surgical aortic valves, needs to be also anticipated: for example, a supra-annular TAV should be considered as the preferred strategy in case of degenerated intraannular TAV, particularly in case of small anatomies. 5…”
mentioning
confidence: 99%
“…The TAV-in-TAV implantation technique has been subject to numerous studies. Initially, Sathananthan et al ( 31 ) assessed the performance of various THV models (SAPIEN 3, Evolut PRO, ACURATE neo, ALLEGRA, and Portico). Multiple THV implantation depths were tested and are summarized in Figure 2 .…”
Section: Introductionmentioning
confidence: 99%
“…Lastly, the phenomenon of leaflets' pinwheeling, characterized by the twisting of the leaflet-free edges due to excessive leaflet redundancy, has been studied. Excessive pinwheeling was observed when implanting a Sapien 3 in a Sapien XT ( 31 ). This observation was recently confirmed by Meir et al ( 34 ) who investigated the expansion of TAV-in-TAV using a Sapien 3 (23 mm) in a Sapien XT/3 (23 mm).…”
Section: Introductionmentioning
confidence: 99%
“…coronary obstruction and affect the risk of patientprosthesis mismatch (PPM). Prior investigations, using benchtops, [6][7][8][9] have demonstrated sizing compatibilities between various TAVs, but these are based on a fully expanded index TAV. Most TAVs, however, are underexpanded in vivo, 10 and although in theory, they can be further expanded to nominal size, such further expansion may increase the risk of annular injury and coronary complications.…”
mentioning
confidence: 99%