2020
DOI: 10.1111/jce.14426
|View full text |Cite
|
Sign up to set email alerts
|

Repeat pulmonary vein isolation with or without FIRM‐guided ablation for recurrent atrial fibrillation with pulmonary vein reconnection

Abstract: Introduction: Focal impulse and rotor modulation (FIRM) ablation can be used to target nonpulmonary vein (PV) sources of atrial fibrillation (AF). No published studies have compared freedom from atrial fibrillation (FFAF) after pulmonary vein reisolation (PVRI) plus FIRM to PVRI alone in patients with reconnected PVs undergoing repeat ablation. Methods: A 3:1 matched retrospective cohort study was performed on 21 patients with recurrent AF and PV reconnection who underwent PVRI plus FIRM-guided ablation and 63… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
12
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 27 publications
0
12
0
Order By: Relevance
“…Pooled data from three studies (OASIS, FIRMAP AF, and Peigh et al 9 ) did not reveal a statistically significant difference in complication rates between FIRM‐guided ablation ± PVI and PVI (RR: 1.66; 95% CI: 0.08–34.54; p = .74) (Figure 6).…”
Section: Resultsmentioning
confidence: 95%
See 2 more Smart Citations
“…Pooled data from three studies (OASIS, FIRMAP AF, and Peigh et al 9 ) did not reveal a statistically significant difference in complication rates between FIRM‐guided ablation ± PVI and PVI (RR: 1.66; 95% CI: 0.08–34.54; p = .74) (Figure 6).…”
Section: Resultsmentioning
confidence: 95%
“…In CONFIRM trial, consecutive cases were prospectively enrolled in a 1:2 case cohort design of FIRM‐guided ablation versus PVI 1 . The two remaining studies by Kirzner et al 8 and Peigh et al 9 were retrospective studies.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The CBA procedural protocol used in this study has been published previously. 5,15 All procedures were performed by board certified electrophysiologists with extensive ablation experience. Briefly, after transeptal catheterization, an Arctic Front Advance (Medtronic Inc.) cryoballoon catheter and Achieve catheter (Medtronic Inc.) were introduced into the left atrium (LA) using the FlexCath Advance Steerable Sheath (Medtronic Inc.).…”
Section: Procedural Detailsmentioning
confidence: 99%
“…Fig 5. Demonstration of a local efficiency curve simulating from a clinical AF map (Subject 841-004, Sarkozy et al 2020[25]), which could be integrated into CARTOFINDER rotational activity analysis interface in the Carto 3 mapping system.…”
mentioning
confidence: 99%