2012
DOI: 10.2106/jbjs.k.00158
|View full text |Cite
|
Sign up to set email alerts
|

Repair Integrity and Functional Outcomes After Arthroscopic Suture-Bridge Rotator Cuff Repair

Abstract: Arthroscopic suture-bridge repair of full-thickness rotator cuff tears was followed by a re-tear rate of 15% as seen with imaging and resulted in significant improvement of functional outcomes and clinical results compared with the preoperative findings.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
52
1
1

Year Published

2013
2013
2019
2019

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 75 publications
(57 citation statements)
references
References 32 publications
3
52
1
1
Order By: Relevance
“…This review found that re-tear rates were found between 7 and 17 % in tears <1 cm and 41-69 % in tears greater than 5 cm; other studies corroborate this finding in re-tears based on the size of the tear [84]. Systematic literature reviews have not found a significant difference in percentage of re-tears based on the technique used for cuff repair, nor have more recent articles comparing newer techniques of fixation such as the suturebridge technique [85,86]. There has also been recent focus to determine whether or not clinical results are associated with the ultimate integrity of the repair; however, patients are found to do well clinically even when their repairs have failed radiographically [87][88][89][90][91].…”
Section: Osteonecrosismentioning
confidence: 81%
“…This review found that re-tear rates were found between 7 and 17 % in tears <1 cm and 41-69 % in tears greater than 5 cm; other studies corroborate this finding in re-tears based on the size of the tear [84]. Systematic literature reviews have not found a significant difference in percentage of re-tears based on the technique used for cuff repair, nor have more recent articles comparing newer techniques of fixation such as the suturebridge technique [85,86]. There has also been recent focus to determine whether or not clinical results are associated with the ultimate integrity of the repair; however, patients are found to do well clinically even when their repairs have failed radiographically [87][88][89][90][91].…”
Section: Osteonecrosismentioning
confidence: 81%
“…A modification of the double-row technique is the double-row suture bridge technique [36,[53][54][55][56] . Gartsman et al [54] , evaluated the repair integrity of single-row vs double-row suture bridge arthroscopic rotator cuff repairs in a prospective, randomized study.…”
Section: Muscle-tendon Unit Retractionmentioning
confidence: 99%
“…Several techniques have been described for double row suture bridge repair. Kim et al [55] compared three different methods including knotted and knotless techniques and demonstrated equivalence between techniques with regards to functional outcomes and repair integrity. An alternative to double row repairs for improving fixation and healing is to increase the number of sutures per anchor.…”
Section: Muscle-tendon Unit Retractionmentioning
confidence: 99%
“…pain relief and a return of function despite a lack of healing 1,[12][13][14] . The rate and cause of successful and unsuccessful outcomes with failed rotator cuff repair is unclear.…”
mentioning
confidence: 99%