2003
DOI: 10.1016/s0021-9797(02)00008-5
|View full text |Cite
|
Sign up to set email alerts
|

Removal of phosphate by aluminum oxide hydroxide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

11
143
3
4

Year Published

2006
2006
2016
2016

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 342 publications
(161 citation statements)
references
References 9 publications
11
143
3
4
Order By: Relevance
“…The phosphate-modified alumina was prepared by immersion of an electrogenerated alumina into a 4 mM NaH 2 PO 4 solution. During this immersion the alumina surface was modified thanks to an efficient phosphate adsorption [23].…”
Section: Structure Of the Investigated Adsorbentsmentioning
confidence: 99%
“…The phosphate-modified alumina was prepared by immersion of an electrogenerated alumina into a 4 mM NaH 2 PO 4 solution. During this immersion the alumina surface was modified thanks to an efficient phosphate adsorption [23].…”
Section: Structure Of the Investigated Adsorbentsmentioning
confidence: 99%
“…The adsorption-desorption of phosphate on aluminum hydroxides and oxides has been the subject of intense study for decades [5][6][7][8][9][10]. Some of the studies aimed at a better understanding of the adsorption mechanisms of strongly bound anions on aluminum (hydr)oxides.…”
Section: E-mail Address: Wgds@rceesaccn (D Wang)mentioning
confidence: 99%
“…The surface charge, Q H (mol L −1 ), was calculated directly from the measured pH and the amount of acid or base added at each data point [9,10] as follows: where C A and C B (mol L −1 ) were the concentrations of acid and base added to the suspension, respectively. Since the titration procedure was finished within 5 h and in the moderate pH domain (4-10), the dissolution of the samples were negligible (Fig.…”
Section: Potentiometric Titrationsmentioning
confidence: 99%
“…19), 20) In Japan, various harmful anions in wastewater such as nitrate, nitrite and fluoride, as well as phosphate are regulated by Water Pollution Control Law (Law number 138 of 1970) proclaimed by the Ministry of the Environment, Government of Japan. It should be noted that the regulated value for aqueous fluoride was revised in 2007 from 15-50 mg/L to 8 mg/L, indicating that candidate removal reagent should be examined as soon as possible for their ability to remove aqueous fluoride.…”
Section: Introductionmentioning
confidence: 99%