2012
DOI: 10.1016/j.jhazmat.2012.07.034
|View full text |Cite
|
Sign up to set email alerts
|

Removal of blue-green algae using the hybrid method of hydrodynamic cavitation and ozonation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
47
0
5

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 95 publications
(53 citation statements)
references
References 54 publications
1
47
0
5
Order By: Relevance
“…Combining cavitation and ozonation process can overcome this limitation since high fluid turbulence created by cavitation phenomena can enhance the rate of mass transfer of ozone in aqueous solutions [29]. Beneficial effects of combined process are also due to the decomposition of ozone in the presence of cavitation to produce atomic oxygen (O), which after reacting with water generates highly reactive hydroxyl radicals [30][31][32][33][34][35][36]. In addition to this hydroxyl radicals are also generated by the dissociation of water due to cavitational effects.…”
Section: Effect Of Loading Of Ozone On Efficacy Of Combined Process mentioning
confidence: 99%
See 2 more Smart Citations
“…Combining cavitation and ozonation process can overcome this limitation since high fluid turbulence created by cavitation phenomena can enhance the rate of mass transfer of ozone in aqueous solutions [29]. Beneficial effects of combined process are also due to the decomposition of ozone in the presence of cavitation to produce atomic oxygen (O), which after reacting with water generates highly reactive hydroxyl radicals [30][31][32][33][34][35][36]. In addition to this hydroxyl radicals are also generated by the dissociation of water due to cavitational effects.…”
Section: Effect Of Loading Of Ozone On Efficacy Of Combined Process mentioning
confidence: 99%
“…Mass transfer resistances offered for the dissolution of ozone in aqueous solution are also reduced by virtue of cavitation [29][30][31][32][33][34][35][36].…”
Section: Effect Of Loading Of Ozone On Efficacy Of Combined Process mentioning
confidence: 99%
See 1 more Smart Citation
“…However, the discharge of excessive nitrogen-containing and phosphatecontaining nutrients into the natural environment has led to increased blue-green algal (i.e. cyanobacterial) blooms in water bodies since the 1950s (Wu et al, 2012). Surface cyanobacterial blooms in eutrophic lakes and rivers have been recognized as a serious environmental problem (Smith et al, 1999).…”
Section: Introductionmentioning
confidence: 99%
“…Compared to acoustic cavitation, HC is more energy efficient and better suited to large scale applications (Gogate, 2007;Sivakumar and Pandit, 2002;Wu et al, 2012). However, until now studies were limited to analyses on water disinfection by disruption of Escherichia coli (Chand et al, 2007;Mezule et al, 2009) and zooplankton (Sawant et al, 2008), and little information is available in the literature on the removal of algae by HC (Gogate, 2011;Gogate and Kabadi, 2009;Nakano et al, 2001).…”
Section: Introductionmentioning
confidence: 99%