Remotely operated infrared radiometer for the measurement of atmospheric water vapor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2004
2004
2013
2013

Publication Types

Select...
4
2

Relationship

4
2

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…IRMA data collection scans typically generate around 500 bytes every 4 seconds. 1 It is possible to exhaust the non-volatile memory resources on a Rabbit microcontroller module in a short amount of time, if the program writer is not careful. Since the Rabbit is a diskless system and relies on its flash memory chip for permanent storage, including storage space for its executable program, simulated disk file systems can be no larger than the remaining memory.…”
Section: Hardware / Software Design Considerationsmentioning
confidence: 99%
See 1 more Smart Citation
“…IRMA data collection scans typically generate around 500 bytes every 4 seconds. 1 It is possible to exhaust the non-volatile memory resources on a Rabbit microcontroller module in a short amount of time, if the program writer is not careful. Since the Rabbit is a diskless system and relies on its flash memory chip for permanent storage, including storage space for its executable program, simulated disk file systems can be no larger than the remaining memory.…”
Section: Hardware / Software Design Considerationsmentioning
confidence: 99%
“…The resulting data will then be used to correct phase distortion contained in the signal data and thereby increase the angular resolution of the telescope. 1 IRMA is being developed with the goal of performing phase correction for the Atacama Large Millimeter Array (ALMA), which will be the world's most powerful ground-based telescope, when completed early in the next decade.…”
Section: Introductionmentioning
confidence: 99%
“…5 In summary, it consists of a 35 x 22 x 19 cm aluminium box weighing just over 13 kg. The box contains a Honeywell-Hymatic Stirling cycle cooler, an attached vacuum vessel containing the 20 µm detector and long pass filter, a chopper blade, a 10 cm off-axis parabolic mirror, a warm blackbody calibration source and all the required power supplies, electronics and microprocessor needed to operate the instrument.…”
Section: Introductionmentioning
confidence: 99%
“…In our application, an infrared radiometer operating at ∼20 μm, [1,2], zinc selenide (ZnSe) meets nearly all the above requirements, however, it suffers from large reflective surface losses due to its high refractive index, n ZnSe 2:46, which results in a transmission of ∼60% in the 10-20 μm range. We have therefore developed a simple, yet effective method for antireflection coating ZnSe that raises its transmission to over 90% in this spectral range.…”
Section: Introductionmentioning
confidence: 99%