2016
DOI: 10.1134/s1061830916080064
|View full text |Cite
|
Sign up to set email alerts
|

Remote testing of high-voltage insulators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 2 publications
0
3
0
1
Order By: Relevance
“…Thus, the performed bench tests and field tests of the developed methodology and measuring complex [6,12] showed the real possibility of its use for monitoring the state of HVIs in operation.…”
Section: Discussionmentioning
confidence: 92%
See 1 more Smart Citation
“…Thus, the performed bench tests and field tests of the developed methodology and measuring complex [6,12] showed the real possibility of its use for monitoring the state of HVIs in operation.…”
Section: Discussionmentioning
confidence: 92%
“…Corresponding to them are the defects, most often in the form of spherical air cavities inside dielectrics and plane-parallel air layers inside the dielectric and at the "dielectric -electrode" interface (disk cavities). The detection of extra-large PD (extralarge PD) and the developed set of diagnostic parameters for their detection have already been reported before [11][12][13][14][15]. However, the physical principles of the development of defects in polymeric materials under the action of extra-large PD have not been developed, and models of progressing defects and residual life based on new diagnostic parameters have not been built [16][17].…”
Section: Control Of Defects Using Partial Dischargesmentioning
confidence: 99%
“…Therefore, the conditions for measuring a set of PD characteristics, to assess the HVI defects, are periodically improved, which is reflected in Russian and International standards. Moreover, at the beginning of the XXI century, it was theoretically predicted [3][4][5][6], and then experimentally established [7][8][9][10][11][12][13][14][15][16], that powerful PDs can also cause degradation of the HVI dielectric materials. However, the processes of PD generation under the action of high voltage are still poorly understood.…”
Section: Introductionmentioning
confidence: 99%
“…As is known from theoretical and experimental studies [7,8], surface cracks on or bulk cavities in the dielectric rod are the main types of defects in highvoltage insulators (HVI). Another type of defects is loose connection between the core and the end terminal.…”
Section: Introductionmentioning
confidence: 99%