2017
DOI: 10.1016/j.jtice.2016.12.001
|View full text |Cite
|
Sign up to set email alerts
|

Remediation of waste water by Co–Fe layered double hydroxide and its catalytic activity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(16 citation statements)
references
References 58 publications
0
16
0
Order By: Relevance
“…by knowing R L parameter value we can predict whether the shape of the isotherm is favorable (0 where, Q e (mg/g) is the amount of adsorbed substances, C e (mg/l) is the concentration at equilibrium, K F (mg/g) is freundlich constant that gives information about adsorption capacity of adsorbed molecules onto catalyst www.nature.com/scientificreports www.nature.com/scientificreports/ surface 15 and n is freundlich constant. 1/n give indication about adsorption intensity and surface heterogeneity 83 . 1/n usually < 1, if favorable adsorption 84 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…by knowing R L parameter value we can predict whether the shape of the isotherm is favorable (0 where, Q e (mg/g) is the amount of adsorbed substances, C e (mg/l) is the concentration at equilibrium, K F (mg/g) is freundlich constant that gives information about adsorption capacity of adsorbed molecules onto catalyst www.nature.com/scientificreports www.nature.com/scientificreports/ surface 15 and n is freundlich constant. 1/n give indication about adsorption intensity and surface heterogeneity 83 . 1/n usually < 1, if favorable adsorption 84 .…”
Section: Resultsmentioning
confidence: 99%
“…The BET (Brunauer, Emmett, and Teller) surface area of the as prepared materials was calculated from adsorption isotherms using a Quantachrome NOVA Automated Gas Sorption System. Zeta potential and partial size measurements were performed on a Malvern instrument (Malvern Instruments Ltd) 83 .…”
Section: Synthesis Ni/fe Ldhmentioning
confidence: 99%
“…An inert nitrogen gas with a flow rate 70 ml/min used to preheat the catalyst to 500 °C for 10 min and acetylene gas passed over the catalyst bed with a rate of 10 ml/min for 30 min. The maximum carbon yield % is produced at 500 °C decomposition temperature as discussed recently by Abdel Moaty et al [31]. Then, the product on the alumina cell was cooled to room temperature.…”
Section: Cnts Synthesis Using Co-fe Layered Double Hydroxide (Ldh) Asmentioning
confidence: 96%
“…In the LDH phase, the molar ratio of Zn/Fe was 4:1. 33 Originally, an aqueous solution of TNT was sonicated for 30 min in 4 M NaOH solution. Solutions of Cu 2+ and Fe 3+ were included drop-wise under vigorous stirring until a pH 10.…”
Section: Preparation Of Tnt/cufe 2 O 4 /Zn-fe Mmomentioning
confidence: 99%
“…32 In specific cases, inorganic NPs inhibit the cellular efflux pump by disturbing the Ca 2+ concentration. 33 So far, the researchers denoted the efficacy of inorganic NPs in cancer therapy, but the main limitation is the only concern at high concentration. Additionally, the issue of cell penetration, translocation and subsequent aggregation inside the cell, or in the cellular compartments is still a critical case.…”
mentioning
confidence: 99%