2017
DOI: 10.1117/12.2253086
|View full text |Cite
|
Sign up to set email alerts
|

Reliable glucose monitoring by ex-vivo blood microdialysis and infrared spectrometry for patients in critical care

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…Advantageously, this biosensor quantified other small molecules including glycerol. Since then, numerous biosensors coupled to microdialysis for the quantification of molecules found in body fluids, tissues, and organs other than the brain have been reported [ 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 , 78 ]. An earlier review of biochemical monitoring of various bodily fluids has been presented elsewhere [ 79 ].…”
Section: Review Of Sensor Technologies For Brain Metabolismmentioning
confidence: 99%
See 2 more Smart Citations
“…Advantageously, this biosensor quantified other small molecules including glycerol. Since then, numerous biosensors coupled to microdialysis for the quantification of molecules found in body fluids, tissues, and organs other than the brain have been reported [ 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 , 78 ]. An earlier review of biochemical monitoring of various bodily fluids has been presented elsewhere [ 79 ].…”
Section: Review Of Sensor Technologies For Brain Metabolismmentioning
confidence: 99%
“…Various applications of optical sensing have been performed both in a label-free or label-based manner. For label-based detection, the optical signal is acquired by fluorescent or colorimetric techniques [ 95 , 96 , 97 , 98 ], whereas label-free techniques involve light–analyte interactions to facilitate signal detection exemplified by spectroscopic biosensors [ 49 , 64 , 65 , 66 , 67 , 68 , 69 , 99 ]. Other than the widely used offline ISCUSflex colorimetric bedside analyser, all optical based techniques integrated with microdialysis to quantify TBI metabolites have utilised infrared spectroscopic sensors.…”
Section: Review Of Sensor Technologies For Brain Metabolismmentioning
confidence: 99%
See 1 more Smart Citation
“…Due to hydrogen bonding effects between water and glycerol, CLS methods need additional attentiveness within the spectral region around 1000 cm −1 , which will be discussed in the following section. Another option is certainly the application of partial least squares (PLS) analysis, which requires formulated samples with varying concentrations of all constituents for calibration [22,30,31]. An advantage, compared with the CLS method, is the inclusion of compounds with pH-dependent vibrational bands, e.g., as experienced for the inorganic phosphate spectra.…”
Section: Quantification Of Insulin and Excipients In Formulationsmentioning
confidence: 99%
“…Several research groups have worked with systems for biomedical laser spectroscopy in the mid-infrared following the commerical availability of EC-QCLs. These systems have mainly used either free-space configurations with liquid samples in transmission cells, 2,3 or fiber-coupled setups with either transmission, reflectance, or attenuated total reflection (ATR) sensing modalities. [4][5][6][7] Fiber-coupled setups are more practical for portable sensor development, while free-space setups can potentially be used for larger systems in e.g.…”
Section: Introductionmentioning
confidence: 99%