2021
DOI: 10.1155/2021/6637335
|View full text |Cite
|
Sign up to set email alerts
|

Reliability Test Rig of the Motorized Spindle and Improvements on Its Ability for High‐Speed and Long‐Term Tests

Abstract: To realize the accurate performance test under high-speed operation and the long-term stable reliability test of the motorized spindle, a reliability test rig (RTR) which can simulate the cutting force in the actual machining process is presented. Firstly, a reasonable prototype integrating dynamic force loading devices and torque loading devices is designed and established based on the load analysis of the spindle, and a complete and explicit control strategy of the reliability loading test is designed. Secon… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 35 publications
0
5
0
Order By: Relevance
“…It is worth noting that none of the fault samples are misclassified as healthy samples, which can ensure the safe operation of the motor. Here, to further illustrate the extensive applicability of the proposed method, a laboratory bearing of the motorized spindle test rig (MSTR) [46] is separately conducted to acquire data and analysis. The overall test rig is illustrated in Figure 19, which consists of a supporting system, a loading system, a force convert system and an accessory system.…”
Section: Fault Dataset Descriptionmentioning
confidence: 99%
See 4 more Smart Citations
“…It is worth noting that none of the fault samples are misclassified as healthy samples, which can ensure the safe operation of the motor. Here, to further illustrate the extensive applicability of the proposed method, a laboratory bearing of the motorized spindle test rig (MSTR) [46] is separately conducted to acquire data and analysis. The overall test rig is illustrated in Figure 19, which consists of a supporting system, a loading system, a force convert system and an accessory system.…”
Section: Fault Dataset Descriptionmentioning
confidence: 99%
“…To align with the experiment of case study 1, the sampling frequency of the vibration data is set to 12 kHz. The rotation speed of the bearing is consistent with that of the motorized spindle, and two working conditions with a large difference are selected for experimental verification according to the reliability test conditions in the literature [46], which are 5000 rpm (C1) and 1000 rpm (C2), respectively. Four kinds of health conditions Here, to further illustrate the extensive applicability of the proposed method, a laboratory bearing of the motorized spindle test rig (MSTR) [46] is separately conducted to acquire data and analysis.…”
Section: Fault Dataset Descriptionmentioning
confidence: 99%
See 3 more Smart Citations