2015
DOI: 10.3233/bme-151550
|View full text |Cite
|
Sign up to set email alerts
|

Reliability performance of titanium sputter coated Ni–Ti arch wires: Mechanical performance and nickel release evaluation

Abstract: The present research was aimed at developing surface coatings on NiTi archwires capable of protection against nickel release and to investigate the stability, mechanical performance and prevention of nickel release of titanium sputter coated NiTi arch wires. Coated and uncoated specimens immersed in artificial saliva were subjected to critical evaluation of parameters such as surface analysis, mechanical testing, element release, friction coefficient and adhesion of the coating. Titanium coatings exhibited hig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(13 citation statements)
references
References 20 publications
0
11
0
Order By: Relevance
“…Glass cover slips were coated with Ti using a Ti target (99.995% purity [4N], from Kurt J. Lesker Company) in an RF diode sputtering system (Leybold Z400, Leybold). Ti sputtering creates a very smooth layer of Ti coating (Anuradha et al 2015), enabling us to perform live-cell imaging of cells adhering to and spreading on Ti. This novel method can be used in detailed, high-resolution studies of cell adherence to Ti.…”
Section: Methodsmentioning
confidence: 99%
“…Glass cover slips were coated with Ti using a Ti target (99.995% purity [4N], from Kurt J. Lesker Company) in an RF diode sputtering system (Leybold Z400, Leybold). Ti sputtering creates a very smooth layer of Ti coating (Anuradha et al 2015), enabling us to perform live-cell imaging of cells adhering to and spreading on Ti. This novel method can be used in detailed, high-resolution studies of cell adherence to Ti.…”
Section: Methodsmentioning
confidence: 99%
“…Concerning biocompatibility, nickel is carcinogenic, mutagenic, and cytotoxic. According to Anuradha et al .,[3] titanium sputter coated nickel titanium (NiTi) archwires seem to be promising for nickel sensitive patients. It showed a reduced surface roughness, friction coefficient, good adhesion and minimal hardness, and elastic modulus variations in artificial saliva over a given time period.…”
Section: Introductionmentioning
confidence: 99%
“…The thickness of the coating is an essential factor, which is closely related to the expression of torque. The thickness of the coating achieved by the PVD is thinner than that by electroplating and electroless plating [22,23,24]. Anuradha P [23] et al reported a uniform, dense titanium coating layer, which was observed by magnetron sputtering, where the thickness varied from3-5 µm.…”
Section: Discussionmentioning
confidence: 99%
“…The thickness of the coating achieved by the PVD is thinner than that by electroplating and electroless plating [22,23,24]. Anuradha P [23] et al reported a uniform, dense titanium coating layer, which was observed by magnetron sputtering, where the thickness varied from3-5 µm. Woowa [22] aesthetic archwire has a compound double-layered coating structure with a silver and platinum coating inside and a special polymer coating outside where the thickness is 10 µm.…”
Section: Discussionmentioning