Reliability of Urinary Albumin, Total Protein, and Creatinine Assays after Prolonged Storage

Abstract: Conclusions: Measurements of urinary albumin, total protein, and albumin-to-creatinine ratio are minimally affected by storage at ؊70°C for approximately 2.5 yr. Prolonged storage results in small decreases of urinary albumin and protein that do not substantially affect phenotype classification of overt renal disease.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 20 publications
0
14
0
Order By: Relevance
“…Samples were stored at room temperature and a urinalysis was performed within 4 h. Hematuria was defined as >30 erythrocytes/high power field (HPF; 40× objective), pyuria as >5 leukocytes/HPF and bacteriuria as the presence of any microscopically detected bacteria; dogs with any of these findings were excluded from the proteinuria analyses. A UPC was performed the same day (48 samples) or on an aliquot that had been stored at −80 °C (nine samples) for up to 18 months (Parekh et al, 2007). Urine protein was determined using a colorimetric method and urine creatinine was determined by a modified Jaffe procedure on an automated chemistry analyzer (OSU group: Roche Hitachi 911 Chemistry analyzer, Roche Diagnostics; UMN group: AU480 Chemistry analyzer, Beckman Coulter).…”
Section: Methodsmentioning
confidence: 99%
“…Samples were stored at room temperature and a urinalysis was performed within 4 h. Hematuria was defined as >30 erythrocytes/high power field (HPF; 40× objective), pyuria as >5 leukocytes/HPF and bacteriuria as the presence of any microscopically detected bacteria; dogs with any of these findings were excluded from the proteinuria analyses. A UPC was performed the same day (48 samples) or on an aliquot that had been stored at −80 °C (nine samples) for up to 18 months (Parekh et al, 2007). Urine protein was determined using a colorimetric method and urine creatinine was determined by a modified Jaffe procedure on an automated chemistry analyzer (OSU group: Roche Hitachi 911 Chemistry analyzer, Roche Diagnostics; UMN group: AU480 Chemistry analyzer, Beckman Coulter).…”
Section: Methodsmentioning
confidence: 99%
“…An extended storage period may be associated with sample degradation over time. The general contemporary consensus is that biosamples stored at 220°C for long periods of time are not recommended for use in scientific studies of biomarkers, given the known degradation of common analytes over time (4)(5)(6). An important reason samples stored at 220°C are suboptimal is that freeze-thaw cycles can still occur at 220°C.…”
Section: Biomarker Degradation During Long-term Storagementioning
confidence: 99%
“…Urine specimens demonstrate a high degree of variability in volume, protein concentration (particularly in the case of kidney damage or dysfunction), total protein excreted, pH (ranges from 4 to 8), as well as variability in urine components due to age, health, diet, or other factors, proteolysis while the urine stored in the bladder; and degradation of collected urine samples upon storage (25). The range of values observed for these properties is high not only from person to person (26, 27), but also within each individual.…”
Section: Challenges In Urine Collection and Processingmentioning
confidence: 99%