2013
DOI: 10.1186/1471-2474-14-17
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of the standard goniometry and diagrammatic recording of finger joint angles: a comparative study with healthy subjects and non-professional raters

Abstract: BackgroundDiagrammatic recording of finger joint angles by using two criss-crossed paper strips can be a quick substitute to the standard goniometry. As a preliminary step toward clinical validation of the diagrammatic technique, the current study employed healthy subjects and non-professional raters to explore whether reliability estimates of the diagrammatic goniometry are comparable with those of the standard procedure.MethodsThe study included two procedurally different parts, which were replicated by assi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(19 citation statements)
references
References 46 publications
(93 reference statements)
0
19
0
Order By: Relevance
“…Literature sources often do not provide details on the measurement device applied and its possible effects on the natural motion of finger joints [9], [12], [16], [20]. Furthermore, publications addressing the accuracy of joint motion measurements [3], [4], [5], [11], [15] do not provide detailed information on the quantitative analysis of the motion of metacarpophalangeal and interphalangeal articulations. This knowledge gap can be eliminated by merging the results of the above two fields of study and by creating an accurate and complete measurement set.…”
Section: Discussionmentioning
confidence: 99%
“…Literature sources often do not provide details on the measurement device applied and its possible effects on the natural motion of finger joints [9], [12], [16], [20]. Furthermore, publications addressing the accuracy of joint motion measurements [3], [4], [5], [11], [15] do not provide detailed information on the quantitative analysis of the motion of metacarpophalangeal and interphalangeal articulations. This knowledge gap can be eliminated by merging the results of the above two fields of study and by creating an accurate and complete measurement set.…”
Section: Discussionmentioning
confidence: 99%
“…A standard finger goniometer was used to measure the patient's ROM. The intra-rater reliability of goniometric measurement using a standard finger goniometer are 0.89 for MCP flexion and extension indicating a good reliability [28].…”
Section: /28mentioning
confidence: 95%
“…Wrist extension radial deviation syndrome is often the result of an imbalance of strong extrinsic wrist extensors and weak intrinsic muscles of the hand including the lumbricals and interossei [29]. The patient may present with tight wrist extensors on the radial side of the forearm [28]. Furthermore, wrist extension with radial deviation syndrome can slacken the peripheral nerves and lead to neuropathic pain upon lengthening of the nerve during functional activities [28].…”
Section: /28mentioning
confidence: 99%
See 2 more Smart Citations