2014
DOI: 10.1016/j.amjcard.2014.07.037
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of ST-Segment Shifts in the Synthesized V3R–V5R Leads After Coronary Balloon Inflations During Percutaneous Coronary Intervention

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…There are some previous papers reporting a good correlation between synthesized and actual right-sided leads [9][10][11][12]. Correlation coefficients in ECG morphologies between synthesized and actual right-sided chest leads were 0.88-0.97 (p < 0.001) [10].…”
Section: Electrocardiographic Recordings and Data Processing To Obtaimentioning
confidence: 84%
See 1 more Smart Citation
“…There are some previous papers reporting a good correlation between synthesized and actual right-sided leads [9][10][11][12]. Correlation coefficients in ECG morphologies between synthesized and actual right-sided chest leads were 0.88-0.97 (p < 0.001) [10].…”
Section: Electrocardiographic Recordings and Data Processing To Obtaimentioning
confidence: 84%
“…Ventricular outflow tract arrhythmias of different origins have features that are dissociable on synthesized rightsided chest ECGs [9,10]. In addition, the usefulness of synthesized right-sided chest ECGs for diagnosing Brugada syndrome [7] and acute myocardial infarctions involving the RV wall [11,12] has been reported. Synthesized right-sided chest ECGs, which can be derived quickly and non-invasively from standard 12-lead ECG data, can be beneficial to both physicians and patients for early diagnosis and treatment of APE.…”
Section: Potential Of Synthesized Right-sided Chest Ecgs For Diagnosimentioning
confidence: 99%
“…In addition, Katoh et al reported that comparison between the waveforms obtained from the synthesized 18-lead ECG and the actually recorded waveforms in patients transported to the coronary care unit complaining of chest pain revealed high correlations in all ECG parameters, such as the P-wave, QRS, QT time and T-wave characteristics [16]. Recently, Tamura et al reported that there was a strong positive correlation between the degree of ST elevation in syn-V 3R , syn-V 4R and syn-V 5R and the actually recorded degree of ST elevation in V 3R , V 4R and V 5R when the relevant coronary artery was occluded [17].…”
Section: Discussionmentioning
confidence: 97%
“…Still, they are not associated with cardiac mortality (p = 0.9). Data from previous studies indicate that the synthesized ECG can detect abnormalities concerning the right side of the heart with high sensitivity and specificity [33,34]. Therefore, in this study, 18-leads synthesized ECG was used to detect RV lead pathological changes and the influence on hospitalization and mortality among ESRD patients.…”
Section: Discussionmentioning
confidence: 99%