1977
DOI: 10.1001/archpedi.1977.02120220036004
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of Salivary Theophylline as a Guide to Plasma Theophylline Levels

Abstract: \s=b\Simultaneous saliva and plasma theophylline levels in 12 chronic asthmatic children were measured by high pressure liquid chromatography following administration of a theophylline preparation. In five subjects, simultaneous plasma and salivary theophylline were measured one week later. A strongly positive correlation between plasma and salivary theophylline levels was found at all time periods tested.There was no substantial difference in the plasma-saliva theophylline ratio determined one week later. A p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
6
0

Year Published

1981
1981
1992
1992

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(7 citation statements)
references
References 7 publications
(1 reference statement)
1
6
0
Order By: Relevance
“…At the same time, several investigators (6,9,11) have shown that saliva concentration measurement provides a reliable measure of serum concentration. At the same time, several investigators (6,9,11) have shown that saliva concentration measurement provides a reliable measure of serum concentration.…”
mentioning
confidence: 98%
See 1 more Smart Citation
“…At the same time, several investigators (6,9,11) have shown that saliva concentration measurement provides a reliable measure of serum concentration. At the same time, several investigators (6,9,11) have shown that saliva concentration measurement provides a reliable measure of serum concentration.…”
mentioning
confidence: 98%
“…The appearance of sustained-release theophylline preparations has made it possible to obtain stable theophylline concentrations with 12 hourly dosing intervals (4, 10, 13, 15). At the same time, several investigators (6,9,11) have shown that saliva concentration measurement provides a reliable measure of serum concentration. If this is true then treatment with theophylline drugs would be made much easier.…”
mentioning
confidence: 98%
“…S/P ratio of 0.568 0.008 and the same relationship between saliva and plasma was found in subjects of all ages ( Figure 1). Although other laboratories obtained similar ratios in children Eney & Goldstein, 1976;Galant et al, 1977;Kelly et al, 1981;Goldsworthy et al, 1981), Khanna and colleagues (1980) found the saliva theophylline concentrations approximated to 0.76-0.8 of plasma theophylline concentrations in neonates. Further studies are clearly needed to confirm the S/P ratio in neonates found in this study.…”
Section: Resultsmentioning
confidence: 89%
“…standard deviation; range, [4][5][6][7][8][9][10][11][12][13][14][15][16][17] were collected simulta-Theophylline is widely used in the treatment of chronic obstructive airway diseases in children. Because of the low therapeutic index of theophylline ' careful monitoring of serum-theophylline levels has been advocated.…”
Section: Introductionmentioning
confidence: 99%