2021
DOI: 10.1097/rlu.0000000000003774
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of Quantitative 18F-FDG PET/CT Imaging Biomarkers for Classifying Early Response to Chemoradiotherapy in Patients With Locally Advanced Non–Small Cell Lung Cancer

Abstract: Purpose of the Report We evaluated the reliability of 18F-FDG PET imaging biomarkers to classify early response status across observers, scanners, and reconstruction algorithms in support of biologically adaptive radiation therapy for locally advanced non–small cell lung cancer. Patients and Methods Thirty-one patients with unresectable locally advanced non–small cell lung cancer were prospectively enrolled on a phase 2 trial (NCT02773238) and underwent… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 34 publications
(81 reference statements)
0
11
0
1
Order By: Relevance
“…Patients scanned on the GE Discovery STE (GE Healthcare, Waukesha, WI, USA) underwent acquisitions of 5 min per bed position while patients scanned on GE Discovery MI underwent acquisitions of 2.5 min per bed position due to differences in scanner sensitivity. PET ordered subset expectation maximization (OSEM) reconstruction parameters were harmonized between scanners to yield concordant quantitative images [ 53 ]. CT-based attenuation correction (CTAC) of the standardized uptake values (SUV) in quantitative PET was applied [ 54 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Patients scanned on the GE Discovery STE (GE Healthcare, Waukesha, WI, USA) underwent acquisitions of 5 min per bed position while patients scanned on GE Discovery MI underwent acquisitions of 2.5 min per bed position due to differences in scanner sensitivity. PET ordered subset expectation maximization (OSEM) reconstruction parameters were harmonized between scanners to yield concordant quantitative images [ 53 ]. CT-based attenuation correction (CTAC) of the standardized uptake values (SUV) in quantitative PET was applied [ 54 ].…”
Section: Methodsmentioning
confidence: 99%
“…Metabolic tumor volume (MTV) contours were prospectively delineated at each time point under the FLARE-RT trial protocol using a commercially validated semi-automatic gradient-based segmentation tool in MIM (PET Edge, MIM Software, Cleveland, OH, USA) with consensus from a multidisciplinary team, including a board-certified radiation oncologist. MTV contours defined in this way improved repeatability compared to manual contouring and reduced sensitivity to image reconstruction compared to fixed threshold contouring [ 53 ]. MTV contours were then propagated to all co-registered images.…”
Section: Methodsmentioning
confidence: 99%
“…The technique has been utilized in discrimination of lung cancers and prediction of possible responsiveness to treatments. For instance, peak standardized uptake value (SUVpeak) has been reported to be utilized to predict early response for adaptive radiation in locally advanced non-small cell lung cancer ( 45 ). Recent advances in techniques have highlighted the utilization of PET-CT scanning to determine invasiveness of GGNs, and to predict probable response to certain interventions.…”
Section: Novel Approaches For Diagnosis Of Ground-glass Nodulesmentioning
confidence: 99%
“…Otros investigadores, como Horn y su equipo (38) , han encontrado la gran utilidad que puede tener un estudio de PET/CT realizado en los regímenes quimio-radioterapia, pues así sería posible encontrar áreas susceptibles de tratamiento, que no han respondido a la quimioterapia inicial. Reconocen que existen limitaciones y que aún se requieren los resultados de trabajos en curso en varios lugares del mundo.…”
Section: Evaluación Del Efecto Del Tratamiento Seleccionado Para El C...unclassified