2007
DOI: 10.1016/j.jneumeth.2007.05.011
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of motor-evoked potentials in the ADM muscle of older adults

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

12
64
3
1

Year Published

2012
2012
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 58 publications
(80 citation statements)
references
References 17 publications
(34 reference statements)
12
64
3
1
Order By: Relevance
“…With the exception of the stroke group intersession values, in all cases MEP single area and amplitude and MEP mean area ICC values were greater than 0.80 when using six or more MEPs. From these data, and in agreement with previous studies in healthy individuals (Bastani and Jaberzadeh, 2012, Christie, Fling, 2007, Doeltgen, Ridding, 16 2009) and guidelines for clinical use of TMS (Groppa, Oliviero, 2012), we recommend that as few as six MEPs can be used to achieve reliable within session measures for patients with stroke. Six MEPs should also provide reliable intersession measures for people with an intact nervous system.…”
Section: Number Of Responsessupporting
confidence: 87%
See 2 more Smart Citations
“…With the exception of the stroke group intersession values, in all cases MEP single area and amplitude and MEP mean area ICC values were greater than 0.80 when using six or more MEPs. From these data, and in agreement with previous studies in healthy individuals (Bastani and Jaberzadeh, 2012, Christie, Fling, 2007, Doeltgen, Ridding, 16 2009) and guidelines for clinical use of TMS (Groppa, Oliviero, 2012), we recommend that as few as six MEPs can be used to achieve reliable within session measures for patients with stroke. Six MEPs should also provide reliable intersession measures for people with an intact nervous system.…”
Section: Number Of Responsessupporting
confidence: 87%
“…Previous studies examining the reliability of MEPs have mainly focused on hand and forearm muscles (Bastani and Jaberzadeh, 2012, Carroll et al, 2001, Christie et al, 2007, Kamen, 2004, Livingston and Ingersoll, 2008, McDonnell et al, 2004, Mortifee et al, 1994, Ngomo et al, 2012, with a smaller number of studies examining muscles from the lower limb (Cacchio et al, 2009, Cacchio et al, 2011, Tallent et al, 2012, van Hedel et al, 2007, Wheaton et al, 2009). Most authors have reported good or excellent reliability of MEP amplitude measurements within and between sessions but this is not always consistent (Livingston andIngersoll, 2008, McDonnell, Ridding, 2004).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Hundreds of studies in neurologic populations such as stroke and spinal cord injury attribute time-varying change in TMS metrics to physiologic mechanisms underlying disease and recovery (Stinear et al, 2007; Trompetto et al, 2000; Liepert et al, 2000; Wittenberg et al, 2003). However, to ensure that TMS can indeed serve as a clinical tool to track longitudinal processes, it is first critical to understand test-retest reliability of its metrics in healthy individuals (Malcolm et al, 2006; Pourtney and Watkins, 2000; Christie et al, 2007; Doeltgen et al, 2009; De Vet et al, 2006; Mills and Nithi 1997; Kimiskidis et al 2004). …”
Section: Introductionmentioning
confidence: 99%
“…However, the majority defines reliability of metrics for distal muscles of the upper limb (Christie et al, 2007; Kamen, 2004; Livingston and Ingersolle, 2008; Malcolm et al, 2006; McDonnell et al, 2004; Carroll et al, 2001; Bastani and Jaberzadeh, 2012). Distal muscles have been the muscles of choice because they are afforded with prominent cortical representations and substantial corticospinal projections (Malcolm et al, 2006; Kamen, 2004; Brasil-Neto et al, 1992).…”
Section: Introductionmentioning
confidence: 99%