2017
DOI: 10.15412/j.bcn.03080106
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal

Abstract: Introduction:Transcranial magnetic stimulation (TMS) is a useful tool for assessment of corticospinal excitability (CSE) changes in both healthy individuals and patients with brain disorders. The usefulness of TMS-elicited motor evoked potentials (MEPs) for the assessment of CSE in a clinical context depends on their intra-and inter-session reliability. This study aimed to evaluate if removal of initial MEPs elicited by using two types of TMS techniques influences the reliability scores and whether this effect… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
10
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 30 publications
1
10
0
Order By: Relevance
“…The findings of high intra‐session reliability of TMS‐elicited MEPs using both R–R and PEST methods are consistent with those of previous studies, which suggest that a stable estimates of MEPs separated by 20 min of no intervention can be achieved within a session (Bastani & Jaberzadeh, ; Christies et al, ; Hashemirad, Zoghi, Fitzgerald, & Jaberzadeh, ; Vaseghi et al, ). The results also suggest that MEP measurements obtained across two sessions 48 hr apart produces good reliabilities using either R–R or PEST methods.…”
Section: Discussionsupporting
confidence: 89%
“…The findings of high intra‐session reliability of TMS‐elicited MEPs using both R–R and PEST methods are consistent with those of previous studies, which suggest that a stable estimates of MEPs separated by 20 min of no intervention can be achieved within a session (Bastani & Jaberzadeh, ; Christies et al, ; Hashemirad, Zoghi, Fitzgerald, & Jaberzadeh, ; Vaseghi et al, ). The results also suggest that MEP measurements obtained across two sessions 48 hr apart produces good reliabilities using either R–R or PEST methods.…”
Section: Discussionsupporting
confidence: 89%
“…Further, our present study is highly comparable to previous research on SICI reliability which used RMT-based TS intensity (e.g., Corp et al, 2015; O’Leary et al, 2015; Ngomo et al, 2012). Despite the fact that the MEP amplitudes induced by TS here in bothgroups did not significantly differ from 1 mV and using 120%RMT or 1-mV did not lead to significantly different reliability (Hashemirad et al, 2017), it should still be cautious to generalize the satisfactory reliability of SICI in schizophrenia patients observed here to studies using 1-mV TS or other TS intensity in SICI.…”
Section: Discussionmentioning
confidence: 68%
“…Because the effects after a single DC stimulation session last up to a few hours after current offset 50 , 51 , the interval among sessions was sufficient for all neural changes due to tsDCS to have been abolished. Third, because the number of MEPs being acquired affects their reliability 52 , and baseline MEP variability is related to neuroplasticity protocols 53 , large scale studies incorporating I-wave protocols, which are known to contribute to baseline MEP variability, are needed. Optimal stimulation intensities for changes of corticospinal and spinal motor pathways following tsDCS also warrant further investigation, since anodal and cathodal tDCS effects are intensity-dependent manifested in a non-linear fashion 54 .…”
Section: Discussionmentioning
confidence: 99%