2020
DOI: 10.3390/ma13214781
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of Metal 3D Printing with Respect to the Marginal Fit of Fixed Dental Prostheses: A Systematic Review and Meta-Analysis

Abstract: Three-dimensional (3D) printing technologies have been widely used to manufacture crowns and frameworks for fixed dental prostheses. This systematic review and meta-analysis aimed to assess the reliability of the marginal fit of 3D-printed cobalt-chromium-based fixed dental prostheses in comparison to conventional casting methods. Articles published until 25 June 2020, reporting the marginal fit of fixed prostheses fabricated with metal 3D printing, were searched using electronic literature databases. After th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
16
1
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(18 citation statements)
references
References 56 publications
0
16
1
1
Order By: Relevance
“…Microscopic readings showed that implant abutment connection misfit is significantly affected by the digital manufacturing technique, which is in agreement with previous literature. 25 32 The 3DP group showed lower implant abutment misfit than the CAD-cast group. One possible reason is that CAD-cast manufacturing technique is affected by the ability and experience of the laboratory technician in casting the CAD-cast frameworks.…”
Section: Discussionmentioning
confidence: 93%
See 2 more Smart Citations
“…Microscopic readings showed that implant abutment connection misfit is significantly affected by the digital manufacturing technique, which is in agreement with previous literature. 25 32 The 3DP group showed lower implant abutment misfit than the CAD-cast group. One possible reason is that CAD-cast manufacturing technique is affected by the ability and experience of the laboratory technician in casting the CAD-cast frameworks.…”
Section: Discussionmentioning
confidence: 93%
“…A systematic review evaluated the fit of casted, milled and 3DP abutments and found that 3DP had poor internal fit compared to other manufacturing methods, which would ultimately affect the RTV. 32 Several studies showed that misfit ranging between 10 and 150 µm would be clinically acceptable and tolerated in the long term. 37 38 39 41 42 43 RTV describes the amount of force needed to un-torque a screw and it has been used as a measurement of preload in multiple studies to evaluate joint stability.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…45 Several reviews have been published about additively manufactured dental restorations. 2,5,10,46,47 The accuracy of the tooth-and implant-supported restorations has only been documented in general, but this study serves the relevant systematized data about the accuracy of AM fixed implant-supported prostheses exceptionally. Because of the manufacturing and construction differences between tooth-and implant-supported restorations such as scanning of the preparation margin or capturing the virtual position of the implant with scan body, tolerance of marginal gap discrepancies or passivity, fixation type, and the more specific data about implant-supported restorations was required.…”
Section: Discussionmentioning
confidence: 97%
“…Previous systematic reviews have assessed metal AM tooth‐supported fixed or removable prostheses accuracy 10,36–39 . However, studies evaluating the accuracy of the AM implant‐supported prosthesis have not yet been reviewed systematically.…”
mentioning
confidence: 99%