2017
DOI: 10.1136/bjophthalmol-2017-310396
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of Cyclotorsion measurements using Scanning Laser Ophthalmoscopy imaging in healthy subjects: the CySLO study

Abstract: NCT02631369, Results.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(21 citation statements)
references
References 16 publications
0
20
0
Order By: Relevance
“…Normative values of the DFA reported in the literature ranging from 0° to 13° and are not related to the age and refractive error. 15,19,20 The mean DFA obtained by Cyclocheck ® application was 6.39° ± 2.72° (range from −0.40° to 12.76°) in 131 healthy volunteers. Our results are in accordance with the data presented in previous studies.…”
Section: Discussionmentioning
confidence: 95%
See 1 more Smart Citation
“…Normative values of the DFA reported in the literature ranging from 0° to 13° and are not related to the age and refractive error. 15,19,20 The mean DFA obtained by Cyclocheck ® application was 6.39° ± 2.72° (range from −0.40° to 12.76°) in 131 healthy volunteers. Our results are in accordance with the data presented in previous studies.…”
Section: Discussionmentioning
confidence: 95%
“…Shin et al 14 found the mean DFA of 5.13° ± 2.79° in 150 normal individuals. Analyzing torsion with scanning laser ophthalmoscope (SLO), Rohrschneider 19 and Lengwiler et al 20 noted the mean DFA of −5.6° ± 3.3° and 6.6° ± 2.8°, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…OCT is an emerging technique for objective cyclotorsion assessment based on the scanning laser ophthalmoscopy fundus image. Lengwiler et al [9] showed a high inter-(rho = 0.88) and intra-rater (rho = 0.95) reliability of the FPA in healthy subjects measured with the in-built algorithm of the Heidelberg Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany). However, further clinical studies in patients with ocular motor diseases are needed to validate OCT in this context.…”
Section: Discussionmentioning
confidence: 99%
“…However, the latter is invasive and not routinely applicable in daily clinical practice. Optical coherence tomography (OCT) is on the horizon as another objective measurement tool [9]. Subjective and objective cyclotorsion measurements may vary widely and are often not consistent [3,4].…”
Section: Inter-rater Reliability Of Cyclotorsion Measurements Using Fmentioning
confidence: 99%
“…Additionally, the system is prepared to be merged with other imaging modalities such as SLO or/and OCT that can provide high-resolution imaging of the subject's retina and additional information such as cyclotorsion measurement [54]. Adding a module with an extra pair of scanners to the imaging modalities connected to FET via a dichroic mirror inserted, for example, between M5 and L6 opens up the possibility for active correction of the acquired images of the eye.…”
Section: Optical Setupmentioning
confidence: 99%