2021
DOI: 10.1016/j.epsr.2021.107025
|View full text |Cite
|
Sign up to set email alerts
|

Reliability Analysis of Internal Power Supply Architecture of Data Centers in Terms of Power Losses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 27 publications
0
9
0
Order By: Relevance
“…These research works are focused on reducing the number of idle servers based on data traffic and negotiated Service Level Agreements (SLAs) [7], optimizing the number of active servers through virtualization [9]- [11], and location-dependent dynamic resource allocation to control the active servers population at each location [8]. However, none of these research works considers the reliability aspects of the IPSS, since the performance of the IPSS degrades with increasing power losses in the IPSS [5]. Therefore, the outage probabilities of the rack-level PSUs are important to consider for the adequacy of the computational resources in DCs, which can be identified by the LOWP index.…”
Section: List Of Symbolsmentioning
confidence: 99%
See 4 more Smart Citations
“…These research works are focused on reducing the number of idle servers based on data traffic and negotiated Service Level Agreements (SLAs) [7], optimizing the number of active servers through virtualization [9]- [11], and location-dependent dynamic resource allocation to control the active servers population at each location [8]. However, none of these research works considers the reliability aspects of the IPSS, since the performance of the IPSS degrades with increasing power losses in the IPSS [5]. Therefore, the outage probabilities of the rack-level PSUs are important to consider for the adequacy of the computational resources in DCs, which can be identified by the LOWP index.…”
Section: List Of Symbolsmentioning
confidence: 99%
“…The servers contain variable airflow control to ensure the reliable operation of the server cooling system in current technology. The required air flow rate depends on the heat generated by the servers, which determines the required rotational speed and fans' power consumption, shown in (3)- (5). The equivalent thermal resistance, R can be expressed as the ratio of the different of die and ambient temperature and the heat generated by the CPUs [6], as shown in (3).…”
Section: ) Local Cooling Fan Power Consumptionmentioning
confidence: 99%
See 3 more Smart Citations