Relaxation studies on power equipment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(15 citation statements)
references
References 15 publications
0
15
0
Order By: Relevance
“…Another important aspect, reported by many researchers is the influence of several factors, including temperature, rain and electromagnetic disturbances together with transformer's volume/geometry on the FDS measurements [9,19,51,[114][115][116][117][118][119][120][121][122][123][124][125][126][127][128][129][130]. Producing a FDS measure for insulation which does not require volume/geometry might therefore be very helpful.…”
Section: Frequency Domain Spectroscopymentioning
confidence: 99%
See 1 more Smart Citation
“…Another important aspect, reported by many researchers is the influence of several factors, including temperature, rain and electromagnetic disturbances together with transformer's volume/geometry on the FDS measurements [9,19,51,[114][115][116][117][118][119][120][121][122][123][124][125][126][127][128][129][130]. Producing a FDS measure for insulation which does not require volume/geometry might therefore be very helpful.…”
Section: Frequency Domain Spectroscopymentioning
confidence: 99%
“…A further comparison with PDC makes it clear, that while RVM is less noise-sensitive and simpler to set up on-site, the measuring results are sensitive to leakage currents due to the input impedance of the measuring instrument, polluted terminations, length and electrical characteristics of the connecting cable [128]. Furthermore the test duration is often longer and the RVM response depends critically on the charging and grounding duration [129]. Also the transformation of the RV measured data to the frequency domain is more difficult than those measured from PDC.…”
Section: Pdc Rvm or Fds?mentioning
confidence: 99%
“…It is found that the scale factor curve has Fig. 6c, which is a master scale curve computed by averaging the scale factor from several RC equivalent models [8,19,24] …”
Section: Extended Debye Model Responsementioning
confidence: 99%
“…Electric breakdown in air causes an extremely brief electric current to flow through the air pocket. The measurement of partial discharge is the measurement of this breakdown current [11,12].…”
Section: Forces and Torques In Magnetic Field Systemsmentioning
confidence: 99%