“…It has a prominent surface area, strong adsorption capacity, and other advantages, and contains oxygen-containing groups, such as carboxyl, hydroxyl. [66] For tapered optical fibers, the energy outflow from the cladding and the interface between the cladding and the outside serve as the support node. Therefore, the penetration depth at the node can be expressed by the following formula,…”
Section: P E R S O N a L A C C O U N T T H E C H E M I C A L R E C O R Dmentioning
confidence: 99%
“…It has a prominent surface area, strong adsorption capacity, and other advantages, and contains oxygen-containing groups, such as carboxyl, hydroxyl. [66] For tapered optical fibers, the energy outflow from the cladding and the interface between the cladding and the outside serve as the support node. Therefore, the penetration depth at the node can be expressed by the following formula,…”
Section: P E R S O N a L A C C O U N T T H E C H E M I C A L R E C O R Dmentioning
confidence: 99%
“…However, the CNTs solution is difficult to dissolve and usually generates large aggregates due to the intertubular Van der Waals interactions and high chemical inertness, which greatly restrict their sensing application. Using GO as a surfactant to disperse CNTs has been reported [ 33 ]. The combination of MWCNTs and GO offers larger surface area and makes water molecules easily absorbed.…”
Section: Resultsmentioning
confidence: 99%
“…In the RH range from 60% RH to 95% RH, this proposed sensor has shown a sensitivity of 0.15 dB/% RH (R 2 = 0.980) [ 32 ]. The S taper fiber sensor based on GO film (maximum intensity sensitivity –0.361 dB/% RH, maximum wavelength sensitivity 365 pm/% RH) was proposed for measuring RH by Y. Zhao et al [ 33 ]. In those humidity sensors, the RI of the GO will be changed by the interaction of GO and water molecules resulting in the amplitude/wavelength variations of resonance peaks with environmental humidity levels.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, various optical fiber RH sensors have been designed, owing to their small size, fast response, high sensitivity, anti-electromagnetic interference, and corrosion resistance. Many sensing structures for RH measurement have been reported, such as fiber grating [1][2][3], directional coupler [4,5], microfiber resonator [6][7][8][9], fiber interferometer [10][11][12][13][14]. For example, G. Woyessa et al proposed a polycarbonate (PC) based polymer optical fiber Bragg grating (FBG) that can realize RH sensing within the temperature range from 20 °C to 100 °C [2].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the SFT with surface evanescent field can be considered as a compact in-line MZI for sensing due to its advantages of small size, easy fabrication and high sensitivity. Y. Zhao et al proposed a SFT based RH sensor by an in-situ layer-by-layer technique [13], the temperature fluctuations had less than 2 %RH impact on the humidity test during the range of 30 ℃~45 ℃. However, in the limited temperature range of 15 ℃, the temperature-cross sensitivity is unsolved in fact, and the SFT based RH sensor works under the conventional transmission mode, which is limited in the measuring environment with special narrow space.…”
Section: Introductionmentioning