2020
DOI: 10.1109/tmi.2020.2991295
|View full text |Cite
|
Sign up to set email alerts
|

Relative Contributions of Anatomical and Quantum Noise in Signal Detection and Perception of Tomographic Digital Breast Images

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 39 publications
0
8
0
Order By: Relevance
“…Studies have shown that a large quantity of microvascular dilations appear in metastasis lymph nodes, but they belong to dysplasia, with more damaged vessel walls and narrow lumen; nonmetastasis lymph nodes are stimulated by regulatory factors, and there will also be obvious vascular proliferation, But its vascular tissue structure is complete [19][20][21][22]. Moreover, the internal structure of metastasis lymph nodes is abnormal due to tumor cells, and a large quantity of tumor cells destroy the structure of their small blood vessels, resulting in reduced blood supply [23][24][25]. Water widely exists in various tissues and organs and iodine contrast agents are mainly distributed in diseased blood vessels.…”
Section: Discussionmentioning
confidence: 99%
“…Studies have shown that a large quantity of microvascular dilations appear in metastasis lymph nodes, but they belong to dysplasia, with more damaged vessel walls and narrow lumen; nonmetastasis lymph nodes are stimulated by regulatory factors, and there will also be obvious vascular proliferation, But its vascular tissue structure is complete [19][20][21][22]. Moreover, the internal structure of metastasis lymph nodes is abnormal due to tumor cells, and a large quantity of tumor cells destroy the structure of their small blood vessels, resulting in reduced blood supply [23][24][25]. Water widely exists in various tissues and organs and iodine contrast agents are mainly distributed in diseased blood vessels.…”
Section: Discussionmentioning
confidence: 99%
“…The filter used in this study is a space-variant version applied on the DBT projections. The details of these can be also seen in our recent work 51,52 . As described above, we applied the filter to the noisy projections to generate a set of 1152 filtered images.…”
Section: Methods and Resultsmentioning
confidence: 64%
“…The first method for assessing the effect of correlated noise on the quality of digital mammography was to calculate objective image quality metrics commonly used in the literature. [10][11][12][13][14][15] We chose the Structural Similarity Index Measure (SSIM), cross-correlation component of the multiscale SSIM (R*), 12 Peak Signal-to-Noise Ratio (PSNR), Quality Index based on Local Variance (QILV), Normalized Anisotropic Quality Index (NAQI), 10 Mean Normalized Squared Error (MNSE) 11 and Cumulative Probability of Blur Detection (CPBD) 15 to evaluate both sets, since these spatial metrics are widely applied to evaluate medical images. 10 We also calculated the Haar wavelet-based Perceptual Similarity Index (HaarPSI), 13 as a wavelet-based metric.…”
Section: Objective Quality Assessmentmentioning
confidence: 99%
“…For a frequency-based analysis, we measured the power spectrum (PS) to compare the sets in terms of spectral similarity, since the PS can describe the strength of variations in an image at different spatial frequencies. 14 The above metrics were calculated on the raw data (DICOM 'for processing' tag), within the segmented breast, and the resulting index for each objective metric was calculated from the average of the evaluated image set.…”
Section: Objective Quality Assessmentmentioning
confidence: 99%