2015
DOI: 10.1016/j.ecoleng.2015.06.037
|View full text |Cite
|
Sign up to set email alerts
|

Relationship between the removal of organic matter and the production of methane in subsurface flow constructed wetlands designed for wastewater treatment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
17
0
2

Year Published

2016
2016
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 42 publications
(24 citation statements)
references
References 42 publications
1
17
0
2
Order By: Relevance
“…The in situ parameters, pH, ORP and temperature, were measured in each HSSF unit using a portable multiparameter OAKTON (PC650-480485). DO was measured using a portable oximeter (oxi 330i/set Hanna HI 9146-04) López et al, 2015). Aboveground and belowground biomass were obtained by dewatering at 75 °C for 24 h, until reaching constant weight (Neubauer et al, 2012).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The in situ parameters, pH, ORP and temperature, were measured in each HSSF unit using a portable multiparameter OAKTON (PC650-480485). DO was measured using a portable oximeter (oxi 330i/set Hanna HI 9146-04) López et al, 2015). Aboveground and belowground biomass were obtained by dewatering at 75 °C for 24 h, until reaching constant weight (Neubauer et al, 2012).…”
Section: Methodsmentioning
confidence: 99%
“…Proximate analysis was performed for below and aboveground biomass of Phr and Sch. TN was analyzed by digestion and distillation and TP by calcination and colorimetry (Neubauer et al, 2012) (López et al, 2015).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The in situ parameters, such pH, temperature, electrical conductivity (EC), dissolved oxygen (DO), and oxidation-reduction potential (ORP), were measured in situ with all the samples using a multiparametric OAKTON-PC650 (Eutech Instruments; Singapore city Singapore). Conventional wastewater parameters, including chemical oxygen demand (COD), biological oxygen demand (BOD 5 ), total suspended solids (TSS), volatile suspended solids (VSS), ammoniacal nitrogen (NH 4 + -N), and orthophosphate (PO 4 3− -P), were analyzed following standard methods [28]. Total organic carbon (TOC) was measured using a TOC-L CPH analyzer (Shimadzu; Tokyo Japan) equipped with an ASI-L autosampler (Shimadzu; Tokyo Japan).…”
Section: Physicochemical and Water Quality Parametersmentioning
confidence: 99%