Relationship between perfusion index and patent ductus arteriosus in preterm infants

Abstract: Mean ΔPI, ΔPI variability, and mean pre-PI measured 4 h prior to echocardiography detect PDA in preterm infants. PI is dynamic and should be assessed continuously. Perfusion index is a promising bedside measurement to identify PDA in preterm infants.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
15
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 26 publications
(17 citation statements)
references
References 35 publications
0
15
0
Order By: Relevance
“…The plethysmographic signal of pulse oximeter can be used to calculate ratio of the pulsatile and non-pulsatile components, described as Perfusion Index. This has been recently studied and is found to be reasonably predictive of low flow states, including patent ductus arteriosus ( 57 – 59 ). Reference values still need to be established in the preterm infant in whom PI is significantly affected by the transitional circulation, taking up to 72 h for the values to stabilize ( 59 ).…”
Section: Assessment Of Cardiac Output (Co) and Tissue Perfusionmentioning
confidence: 99%
“…The plethysmographic signal of pulse oximeter can be used to calculate ratio of the pulsatile and non-pulsatile components, described as Perfusion Index. This has been recently studied and is found to be reasonably predictive of low flow states, including patent ductus arteriosus ( 57 – 59 ). Reference values still need to be established in the preterm infant in whom PI is significantly affected by the transitional circulation, taking up to 72 h for the values to stabilize ( 59 ).…”
Section: Assessment Of Cardiac Output (Co) and Tissue Perfusionmentioning
confidence: 99%
“…However, some infants with PDA present for evaluation of an asymptomatic heart murmur with no overt clinical manifestations. 22,24,25 Endocan, a chondroitin sulfate/dermatan sulfate proteogly-can, is a novel human endothelial cell-specific molecule and can be measured in serum. The expression and distribution of endocan in normal human tissues such as skin, lungs, gastrointestinal tract, cardiovascular system, normal brain, liver, kidneys, and other organs have been shown.…”
Section: Discussionmentioning
confidence: 99%
“…Pulse oximeters were equipped with serial data recorders (Acumen Instruments Corp.) for continuous data collection. Novel programs were utilized to filter and analyze data (Matlab, Natick, MA, USA) ( 1 , 33 ). Data with artifacts were excluded.…”
Section: Methodsmentioning
confidence: 99%