2019
DOI: 10.1016/j.measurement.2019.05.082
|View full text |Cite
|
Sign up to set email alerts
|

Relationship among hand forces imparted on a viscoelastic hand-handle interface

Abstract: Design of a flexible thin-film hand sensor is presented for reliable measurements of the contact pressure/force distribution at a viscoelastic hand-handle interface, including the contact force developed by a gloved-hand grasping a tool handle. The static properties of the developed hand sensor were evaluated in terms of its drift, linearity, repeatability and hysteresis under global as well as local loads. The measured results revealed low hysteresis (<6%) and drift (≈2.9% over 30s), good linearity (r 2 =0.99… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 40 publications
(55 reference statements)
0
8
0
Order By: Relevance
“…This sEMG sensor and its optimal arrangement was useful for achieving highly accurate individual finger control for the bionic arm and did so relatively cheaply. In a separate development work, Yao et al [ 118 ] proposed a flexible thin-film hand sensor, designed to reliably measure the contact pressure distribution at the viscoelastic handle interface and detect the contact force generated by the limb grasping the tool at that location. Innovatively, Wang et al [ 52 ] constructed a high-performance, energy-efficient, and fully flexible piezoelectric haptic sensor by integrating piezoelectric materials with the electromechanical conversion function and signal of PVDF.…”
Section: Contact Forms Of Flexible Sensorsmentioning
confidence: 99%
“…This sEMG sensor and its optimal arrangement was useful for achieving highly accurate individual finger control for the bionic arm and did so relatively cheaply. In a separate development work, Yao et al [ 118 ] proposed a flexible thin-film hand sensor, designed to reliably measure the contact pressure distribution at the viscoelastic handle interface and detect the contact force generated by the limb grasping the tool at that location. Innovatively, Wang et al [ 52 ] constructed a high-performance, energy-efficient, and fully flexible piezoelectric haptic sensor by integrating piezoelectric materials with the electromechanical conversion function and signal of PVDF.…”
Section: Contact Forms Of Flexible Sensorsmentioning
confidence: 99%
“…Uniaxial grip and push forces have been separately measured directly using an instrumented split handle and a force plate [15]. Those measurements are independently relevant to quantify the health effects and have been extensively used for many years for studying hand-transmitted vibration [16][17][18][19]; however, they have been difficult to implement in real work environments [15]. Similar custom instrumented cylindrical handles have also been used to report force distributions when gripping, pushing and pulling a cylinder [20], but the results are only applicable to those independent actions.…”
Section: Introductionmentioning
confidence: 99%
“…However, relatively thick vibration-reducing materials used in AV gloves generally impede hand performance in view of manual dexterity and grip strength. Wearing gloves usually requires a relatively higher grip exertion by the operators compared with bare hand (BH; Hamouda et al, 2018; Welcome et al, 2012; Willms et al, 2009; Wimer et al, 2009; Yao et al, 2019; Young et al, 2012; Yu et al, 2015). Higher grip strength demand can increase the risk of hand-arm musculoskeletal disorders (MSDs) among operators, such as hand tendonitis, strained muscles, and carpal tunnel syndrome (Chang & Shih, 2007; Silverstein et al, 1987; Wimer et al, 2010).…”
Section: Introductionmentioning
confidence: 99%
“…Such measurement systems are not suited for assessing grip strength reduction by AV gloves, which may alter the distribution of contact pressure and thus force. Alternatively, few studies have developed flexible thin-film sensors and sensing grids for direct measurements of contact force developed at the palmar side surface of a gloved hand grasping a handle (Lemerle et al, 2008; Yao et al, 2019). The application of the glove sensor, however, was reported to be either high-cost and cumbersome, or low-cost but with notable drift (Lemerle et al, 2008; Yao et al, 2019).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation