2014
DOI: 10.1051/epjconf/20136504002
|View full text |Cite
|
Sign up to set email alerts
|

Rejection of randomly coinciding 2ν2β events in ZnMoO4scintillating bolometers

Abstract: Abstract. Random coincidence of 2ν2β decay events could be one of the main sources of background for 0ν2β decay in cryogenic bolometers due to their poor time resolution. Pulse-shape discrimination by using front edge analysis, the mean-time and χ 2 methods was applied to discriminate randomly coinciding 2ν2β events in ZnMoO 4 cryogenic scintillating bolometers. The background can be effectively rejected on the level of 99% by the mean-time analysis of heat signals with the rise time about 14 ms and the signal… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 19 publications
0
1
0
Order By: Relevance
“…In dark-matter searches, a high-performance light detector is required to lower the energy threshold [14] and to identify recoils of different-mass nuclei [15]. In double-beta decay searches, high-sensitivity light detectors are needed either to detect the feeble Cherenkov light emitted by poorlyscintillating crystals [16] (this is the case of the promising compound TeO 2 [17,18,19,20,21]), or to help in pile-up rejection (as in 100 Mo-enriched bolometers, [22,23,24]). The pile-up rejection capability is useful also to perform precision calorimetric measurements of rare-β-decay spectral shapes (as those of 113 Cd and 115 In) which can be used to scrutinize the value of the axialvector coupling constant [25,26,27].…”
Section: Introductionmentioning
confidence: 99%
“…In dark-matter searches, a high-performance light detector is required to lower the energy threshold [14] and to identify recoils of different-mass nuclei [15]. In double-beta decay searches, high-sensitivity light detectors are needed either to detect the feeble Cherenkov light emitted by poorlyscintillating crystals [16] (this is the case of the promising compound TeO 2 [17,18,19,20,21]), or to help in pile-up rejection (as in 100 Mo-enriched bolometers, [22,23,24]). The pile-up rejection capability is useful also to perform precision calorimetric measurements of rare-β-decay spectral shapes (as those of 113 Cd and 115 In) which can be used to scrutinize the value of the axialvector coupling constant [25,26,27].…”
Section: Introductionmentioning
confidence: 99%