2015
DOI: 10.1515/ract-2015-2437
|View full text |Cite
|
Sign up to set email alerts
|

REIMEP-22 inter-laboratory comparison: “U Age Dating – determination of the production date of a uranium certified test sample”

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…For IRMM-1000 both obtained values are slightly lower than the certified age. Although this is not significant, it was also observed during the REIMEP-22 inter-laboratory comparison [ 18 ]. For U100 the measured 231 Pa/ 235 U production dates are in agreement with the purification date of 8 January, 1959 [ 8 ].…”
Section: Resultsmentioning
confidence: 71%
“…For IRMM-1000 both obtained values are slightly lower than the certified age. Although this is not significant, it was also observed during the REIMEP-22 inter-laboratory comparison [ 18 ]. For U100 the measured 231 Pa/ 235 U production dates are in agreement with the purification date of 8 January, 1959 [ 8 ].…”
Section: Resultsmentioning
confidence: 71%
“…The uranium amount per particle and its associated uncertainty as quantied in this study in the particles reference material IRMM-2329P, was further conrmed during the Prociency Test NUSIMEP-9 (Nuclear Signatures Interlaboratory Measurement Evaluation Programme) organised by the JRC-Geel G.2 unit. 20 One NUSIMEP-9 participating laboratory, expert in the eld of particle analysis, using LG-SIMS and calibrating against a specic batch of microspheres CRM U020-A according to Ranebo et al, 21 determined the uranium amount per particle with a relative difference to the reference/certied value of only À0.6%.…”
Section: Discussionmentioning
confidence: 99%
“…Safeguard authorities requirement for 235 U abundance measurement uncertainty by Thermal Ionization Mass Spectrometry (TIMS) is set to 0.28 % (k = 1) [3]. The detection of 234 U is of prime interest in nuclear forensics [4]. Also, for a given sample, the relative amount of 234 U dramatically changes its radiotoxicity [5].…”
Section: Introductionmentioning
confidence: 99%