Regulating the DC Voltage of Capacitive Divider Through Variable Switching Dead-Time in the Three-Phase Inverter With an Active Filter

Abstract: In three-phase inverters, high output common-mode voltage (CMV) will bring many negative effects. The active filter with a capacitive voltage divider (CVD) can effectively suppress the peaks of CMV both in the time-domain and frequency-domain. In practice, it is found that the dc voltage of active filter from the CVD will deviate. In this paper, it is found that the deviation comes from the switching dead-time of the active filter. Based on the study in regard to the influence of switching dead-time on the dc … Show more