Regional investigation of lung function and microstructure parameters by localized 129Xe chemical shift saturation recovery and dissolved‐phase imaging: A reproducibility study

Abstract: Localized Xe CSSR provides reproducible estimates of alveolar wall thickness and is able to detect regional differences of lung microstructure.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
22
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 22 publications
(26 citation statements)
references
References 25 publications
1
22
0
Order By: Relevance
“…The results indicate high repeatability of the whole‐lung mean values, especially for RBC:Barrier. The values we report are generally in agreement with previous estimates measured with whole‐lung spectroscopy and alternative regional spectroscopic imaging methods . It is possible to begin to estimate CR for dissolved‐phase ratios necessary to evaluate progression.…”
Section: Discussionsupporting
confidence: 87%
See 1 more Smart Citation
“…The results indicate high repeatability of the whole‐lung mean values, especially for RBC:Barrier. The values we report are generally in agreement with previous estimates measured with whole‐lung spectroscopy and alternative regional spectroscopic imaging methods . It is possible to begin to estimate CR for dissolved‐phase ratios necessary to evaluate progression.…”
Section: Discussionsupporting
confidence: 87%
“…The values we report are generally in agreement with previous estimates measured with whole-lung spectroscopy 12 and alternative regional spectroscopic imaging methods. 16 It is possible to begin to estimate CR for dissolved-phase ratios necessary to evaluate progression. Based on our Bland-Altman analysis, these CR's are 0.37, 0.14, and 0.09 for whole-lung mean values of the Barrier:Gas, RBC:Gas, and RBC:Barrier ratios, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…The reproducibility of chemical shift saturation recovery measurements in COPD patients has been assessed previously . The microstructural parameters TP wall thickness and TP S/V have similar median coefficients of variation in CSSR mapping (7.4%/7.5%) compared to the results for CSSR spectroscopy obtained in Ref.…”
Section: Discussionmentioning
confidence: 76%
“…The CSSR spectroscopy sequence featured 2.4 ms‐long rectangular saturation pulses centered on the TP or RBC resonance, respectively. After 1 of 21 different delay times, a 1.2 ms‐long Gaussian pulse centered on the 129 Xe dissolved‐phase frequency was irradiated, and the signal acquired at a bandwidth of ± 16.67 kHz and a readout duration of 30.72 ms.…”
Section: Methodsmentioning
confidence: 99%