2008
DOI: 10.1148/radiol.2473071228
|View full text |Cite
|
Sign up to set email alerts
|

Regional Heterogeneity of Air Trapping at Expiratory Thin-Section CT of Patients with Bronchiolitis: Potential Implications for Dose Reduction and CT Protocol Planning

Abstract: The regional distribution of the extent of air trapping in suspected or overt bronchiolitis is heterogeneous. Because the extent of air trapping can depend on the examination protocol, identical protocols are needed when air trapping is being compared within and between patients.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
9
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 31 publications
1
9
0
Order By: Relevance
“…However, both techniques allow only limited assessment of the lung 17 18. In this study, we employed another strategy: we decreased the sampling density of CT scans, thereby reducing the effective scan length and, consecutively, the radiation dose, as previously done by Bankier et al and de Jong et al for other indications 7 8. We could herein demonstrate an estimated dose reduction of more than 90% compared to standard HRCT while maintaining high sensitivity for ILD detection.…”
Section: Discussionmentioning
confidence: 80%
See 1 more Smart Citation
“…However, both techniques allow only limited assessment of the lung 17 18. In this study, we employed another strategy: we decreased the sampling density of CT scans, thereby reducing the effective scan length and, consecutively, the radiation dose, as previously done by Bankier et al and de Jong et al for other indications 7 8. We could herein demonstrate an estimated dose reduction of more than 90% compared to standard HRCT while maintaining high sensitivity for ILD detection.…”
Section: Discussionmentioning
confidence: 80%
“…Various adjustments of acquisition settings have been assessed to reduce radiation, and lowering the tube current is the most widely employed adjustment setting in chest CT 6. Alternatively, a reduced CT scan protocol with a limited number of slices can also be used 7 8. However, this technique carries the risk that with the decrease in image numbers, abnormal findings remain undetected.…”
Section: Introductionmentioning
confidence: 99%
“…A former prospective study by Winklehner et al showed that the use of a dedicated HRCT based on reduced sequential slices throughout the entire chest can detect lung fibrosis with a high diagnostic sensitivity and accuracy of both 94% with a very low radiation dose (28). Similar strategies with the aim of dose reduction in CT for other indications have also been performed by Bankier et al and de Jong et al (29,30). The advantage of a low sampling protocol is the very low radiation dose of less than 0.028 mSv, which is in the range of a chest X-ray (28).…”
Section: Introductionmentioning
confidence: 92%
“…Second, calculation of relative area or volume requires a combination of several esti mates of lung area or volume, which is time consuming because of postpro cessing and possible cumulative errors in calculation. For quantification of small airways obstruction with paired inspiratory and expiratory CT scans, volumetric acquisition should be pre ferred to help overcome possible mis registration if sequential sections are used and to take into account the het erogeneity of air trapping (126).…”
Section: Quantification Of Small Airways Obstructionmentioning
confidence: 99%