2020
DOI: 10.3174/ajnr.a6927
|View full text |Cite
|
Sign up to set email alerts
|

Regional Aneurysm Wall Enhancement is Affected by Local Hemodynamics: A 7T MRI Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
21
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(26 citation statements)
references
References 30 publications
3
21
1
Order By: Relevance
“…However, there is no consensus on how to determine thresholds of AWE or what part of the aneurysm should be sampled to analyze enhancement. 3D maps may also provide further information about the aneurysm biology as it has been shown that aneurysm compartments have different patterns of enhancement directly influenced by local flow conditions 10 . 7T MRI studies have demonstrated a linear correlation between wall thickness and SI.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, there is no consensus on how to determine thresholds of AWE or what part of the aneurysm should be sampled to analyze enhancement. 3D maps may also provide further information about the aneurysm biology as it has been shown that aneurysm compartments have different patterns of enhancement directly influenced by local flow conditions 10 . 7T MRI studies have demonstrated a linear correlation between wall thickness and SI.…”
Section: Discussionmentioning
confidence: 99%
“…Detailed analysis of focal AWE (FAWE) has determined that the colocalization of these areas with low wall shear stress, such as blebs (Fig. 1 ) is associated with a higher risk of rupture 10 , 11 . Other groups determined a higher risk of rupture when circumferential wall enhancement (CAWE) is present, instead of FAWE 1 , 12 , 13 .…”
Section: Introductionmentioning
confidence: 99%
“…Thus, commonly used isotropic voxel sizes range between 0.5 – 0.8 mm 3 . MR imaging at higher magnetic fields (7T or more) can improve the SNR ( 30 ). The development of new acceleration techniques can reduce the examination time ( 31 ) while maintaining or increasing the spatial resolution.…”
Section: Mrimentioning
confidence: 99%
“…However, several studies have suggested using wall enhancement in contrast-enhanced vessel wall magnetic resonance imaging (VW-MRI) as an indirect marker for wall inflammation [18][19][20]. Exemplarily, different flow conditions (e.g., at the neck, aneurysm body or dome) were associated with a varying degree of local enhancement [21]. Furthermore, VW-MRI in combination with flow MRI was used to correlate morphology and haemodynamics in IAs [22].…”
Section: Introductionmentioning
confidence: 99%