2020
DOI: 10.1109/tie.2019.2903750
|View full text |Cite
|
Sign up to set email alerts
|

Regenerative Test for Multiple Three-Phase Machines With Even Number of Neutral Points

Abstract: The version presented here may differ from the published version or from the version of the record. Please see the repository URL above for details on accessing the published version and note that access may require a subscription.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 21 publications
(42 reference statements)
0
7
0
Order By: Relevance
“…However, with the development of the "series/parallel configurations" [17], [44], [45], the control solutions able to perform the power-sharing among the winding sets have gained more attention, leading to several technical contributions [17], [18], [32], [36], [37]. Also, for testing high-power machines, the power-sharing strategies are a viable solution for performing back-to-back regenerative tests [37], [46], [47], thus avoiding the need for expensive highpower prime movers.…”
Section: Comparison Between Dms and Vsd Approachesmentioning
confidence: 99%
“…However, with the development of the "series/parallel configurations" [17], [44], [45], the control solutions able to perform the power-sharing among the winding sets have gained more attention, leading to several technical contributions [17], [18], [32], [36], [37]. Also, for testing high-power machines, the power-sharing strategies are a viable solution for performing back-to-back regenerative tests [37], [46], [47], thus avoiding the need for expensive highpower prime movers.…”
Section: Comparison Between Dms and Vsd Approachesmentioning
confidence: 99%
“…The machine is not coupled to a load drive and both channels of the converter (BRAVO and ECHO) are connected to the same DC power supply. The power supply is capable of maintaining 1.5kV, instead of the nominal value of 3kV, and tests are performed using recirculating power operation of the system [42]- [44]. In Fig.…”
Section: Resultsmentioning
confidence: 99%
“…In two or more inverter systems, low mutual coupling of the abovementioned design requirements is important (Figure 1) because the control complexity of the machine increases with the increase in the number of inverters [11].…”
Section: Introductionmentioning
confidence: 99%