2008
DOI: 10.1109/lpt.2008.919507
|View full text |Cite
|
Sign up to set email alerts
|

Refractive Index Sensing With Mach–Zehnder Interferometer Based on Concatenating Two Single-Mode Fiber Tapers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
135
3

Year Published

2009
2009
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 309 publications
(142 citation statements)
references
References 14 publications
1
135
3
Order By: Relevance
“…Though LPGs have been revealed to possess a high sensitivity to the refractive index of the ambient medium, the typical full width at half maximum of the resonance peak of a LPG is about tens of nanometers, which limits the measurement accuracy and its multiplexing capability. Most recently, optical refractive index sensors or refractometers based on all-fiber interferometers 16,17 or resonators 18 have received considerable attention for their high sensitivity, absolute detection with wavelength codified information, broad measurement range, and compact size. These fiber interferometric techniques are cumbersome systems with high cost and simultaneous sensing of refractive index and temperature is missing.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Though LPGs have been revealed to possess a high sensitivity to the refractive index of the ambient medium, the typical full width at half maximum of the resonance peak of a LPG is about tens of nanometers, which limits the measurement accuracy and its multiplexing capability. Most recently, optical refractive index sensors or refractometers based on all-fiber interferometers 16,17 or resonators 18 have received considerable attention for their high sensitivity, absolute detection with wavelength codified information, broad measurement range, and compact size. These fiber interferometric techniques are cumbersome systems with high cost and simultaneous sensing of refractive index and temperature is missing.…”
mentioning
confidence: 99%
“…In this paper, an in-line one-fiber approach to realize simultaneous measurement of refractive index and temperature is proposed and experimentally demonstrated. Compared with the techniques reported on the interferometers with tapered fibers for sensing applications, 17,19,20 a tapered fiber Mach-Zehnder interferometer ͑FMZI͒ has been fabricated on single-mode fiber by using simple fusion splicing in this study. Analysis on the simultaneous measurement of refractive index and temperature has been carried out to verify the experimental results.…”
mentioning
confidence: 99%
“…index sensors based on measurement of the spectral shifts of transmission peaks. [28][29][30][31][32][33] The phase difference between the sensing arm and the reference arm of the MZI can be expressed as…”
Section: Methodsmentioning
confidence: 99%
“…At the small core fiber region, the beam is guided as the core mode and as well as the cladding mode [7]. Figure 5(f) shows an effective in-line MZI which is formed by tapering a fiber at two points along the fiber [8,9]. The core mode diameter gets increased due to tapering and part of it can be easily coupled to the cladding mode(s).This method is relatively very simple and cost effective but mechanically weak especially at the tapering region.…”
Section: Mach Zehnder Interferometer As Sensorsmentioning
confidence: 99%