2014
DOI: 10.1016/j.jcrs.2013.10.046
|View full text |Cite
|
Sign up to set email alerts
|

Refractive accuracy with light-adjustable intraocular lenses

Abstract: No author has a financial or proprietary interest in any material or method mentioned.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
4

Relationship

2
7

Authors

Journals

citations
Cited by 24 publications
(11 citation statements)
references
References 19 publications
0
11
0
Order By: Relevance
“…In recent years, aberrometry has become a crucial tool in the clinical practice of ophthalmology and optometry. Aberrometers provide a clinical characterization of the ocular optics by measuring objective refraction,6, 7 from lower-order aberrations (LOAs), and higher-order aberrations (HOAs) 8 . Furthermore, aberrometers based on the Hartmann-Shack principle help detect ocular diseases, such as keratoconus and cataract, by analyzing HOAs and Hartmann-Shack images 4, 5…”
mentioning
confidence: 99%
“…In recent years, aberrometry has become a crucial tool in the clinical practice of ophthalmology and optometry. Aberrometers provide a clinical characterization of the ocular optics by measuring objective refraction,6, 7 from lower-order aberrations (LOAs), and higher-order aberrations (HOAs) 8 . Furthermore, aberrometers based on the Hartmann-Shack principle help detect ocular diseases, such as keratoconus and cataract, by analyzing HOAs and Hartmann-Shack images 4, 5…”
mentioning
confidence: 99%
“…After the postoperative refraction has stabilized, the LAL enables residual spherical and cylindrical errors to be corrected or adjusted. [ 20 21 22 ] When the LAL is exposed to the targeted ultraviolet light, a photoinitiator is activated, resulting in selective polymerization of macromers in the lens. The unpolymerized macromers then diffuse to the treated area, producing a predictable shape change that alters the refractive power of the lens.…”
Section: Methods Proposed For Intraocular Lens Power Calculation In P...mentioning
confidence: 99%
“…Some trends suggest future avenues not only for customized IOL selection but also for customized IOL design (149). For example, light-adjustable IOLs aim to intraoperatively fine-tune IOL power (by changing in situ the shape of the IOL by application of UV irradiation) (150). As 3D printing or other technologies for rapid production of opticalgrade (and sterilized) IOLs may become available in the future (151), à la carte prescription of IOLs, specifically designed for a subject by applying optical design optimization techniques to custom computer eye models and visual simulations, can be envisioned.…”
Section: Figure 10mentioning
confidence: 99%