1999
DOI: 10.1097/00005392-199907000-00096
|View full text |Cite
|
Sign up to set email alerts
|

Reflux in Young Patients: Comparison of Voiding US of the Bladder and Retrovesical Space With Echo Enhancement Versus Voiding Cystourethrography for Diagnosis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

3
46
0
1

Year Published

2001
2001
2012
2012

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 114 publications
(50 citation statements)
references
References 1 publication
3
46
0
1
Order By: Relevance
“…The high NPV of Doppler voiding urosonography described in previous studies and in our investigation, especially in younger children, indicates the reliability of this method in this respect. 14 Similar to previously reported investigations, the total duration of the examination applying both direct radionuclide voiding cystography and Doppler voiding urosonography was about 20 to 30 minutes for each patient. Although this process might be regarded as time-consuming, one should not forget that a longer sonographic examination time also improves the probability of detecting intermittent reflux.…”
Section: Discussionsupporting
confidence: 81%
See 1 more Smart Citation
“…The high NPV of Doppler voiding urosonography described in previous studies and in our investigation, especially in younger children, indicates the reliability of this method in this respect. 14 Similar to previously reported investigations, the total duration of the examination applying both direct radionuclide voiding cystography and Doppler voiding urosonography was about 20 to 30 minutes for each patient. Although this process might be regarded as time-consuming, one should not forget that a longer sonographic examination time also improves the probability of detecting intermittent reflux.…”
Section: Discussionsupporting
confidence: 81%
“…In comparison with most available studies, we aimed to assess the diagnostic efficacy of color Doppler voiding urosonography without the application of contrast enhancement. Although echo-enhancing agents were shown to be well tolerated by patients, 14 their availability may be Both direct radionuclide voiding cystography and Doppler voiding urosonography have similar diagnostic capabilities and similar disadvantages. They offer low anatomic resolution and lack visualization of the urethra.…”
Section: Discussionmentioning
confidence: 99%
“…Various authors have described numerous "false-positive" sonographic examination results in low-grade refluxes. [5][6][7][8] There were no special factors involved in our case of grade IV reflux not shown by VCUG. Mentzel et al 6 and Bosio 7 also found grade IV refluxes identified only by EC.…”
Section: Discussionmentioning
confidence: 57%
“…It involves instillation of a contrast-enhancing agent into the bladder to demonstrate or rule out the presence of reflux and to identify associated anomalies of the urinary tract, and it avoids radiation exposure. [2][3][4][5][6][7] Comparative studies between VCUG and EC have shown good results, with sensitivities between 70% and 100% and specificities from 86% to 97%. [5][6][7] We obtained similar values in specificity and negative predictive value (92% and 94%, respectively), but our sensitivity was lower (66%).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation