2019
DOI: 10.1109/tim.2018.2886950
|View full text |Cite
|
Sign up to set email alerts
|

Reflective SPR Sensor for Simultaneous Measurement of Nitrate Concentration and Temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 60 publications
(11 citation statements)
references
References 26 publications
0
10
0
Order By: Relevance
“…In 2019, based on the reflective cascade structure, Zhang et al employed Cu-nanoparticles/carbon nanotubes (CuNPs/CNTs) composite film and PDMS polymer to simultaneously detect nitrate and temperature. [191] The experimental results indicate the sensitivity to nitrate concentration is 3.25 nm lg[m] −1 , and the sensitivity to temperature is −2.02 nm °C−1 . Eventually, the sensitivity coefficient matrix method is utilized to demodulate temperature and nitrate concentration simultaneously.…”
Section: Multichannel Sensing Of Biochemical Moleculesmentioning
confidence: 99%
“…In 2019, based on the reflective cascade structure, Zhang et al employed Cu-nanoparticles/carbon nanotubes (CuNPs/CNTs) composite film and PDMS polymer to simultaneously detect nitrate and temperature. [191] The experimental results indicate the sensitivity to nitrate concentration is 3.25 nm lg[m] −1 , and the sensitivity to temperature is −2.02 nm °C−1 . Eventually, the sensitivity coefficient matrix method is utilized to demodulate temperature and nitrate concentration simultaneously.…”
Section: Multichannel Sensing Of Biochemical Moleculesmentioning
confidence: 99%
“…Therefore, the multi-parameter SPR sensors have attracted much attention [21]. Recently, more and more research has shifted the focus to optical-fiber-based multi-parameter SPR sensors, for example, the simultaneous measurement of salinity, temperature, and pressure [22]; the simultaneous measurement of temperature and magnetic field strength [23]; the simultaneous measurement of solution concentration and temperature [24]; and the simultaneous measurement of RI and temperature [25][26][27][28]. However, to our knowledge, there are few reports about optical-fiber-based SPR sensors for simultaneous measurement of RI and liquid level.…”
Section: Introductionmentioning
confidence: 99%
“…Various methods for creating optical fiber biosensors have been proposed, such as fiber Bragg‐gratings [20–25], long period fiber gratings [26], fiber interferometers [27–30], Brillouin/Raman scattering [31], surface Plasmon resonance [32–35], lossy‐mode resonance [36], interferometer [37–41] and specialty fiber couplers [42]. Among them, the biosensors based on optical fiber interferometer are particularly attractive.…”
Section: Introductionmentioning
confidence: 99%