Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion

Abstract: This is the accepted version of the paper.This version of the publication may differ from the final published version. Permanent repository link

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
73
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 87 publications
(76 citation statements)
references
References 46 publications
2
73
1
Order By: Relevance
“…Eq. 2 shows the application of the modified Beer-Lambert law to single-wavelength PPG signals, assuming constant scattering [8].…”
Section: Signal Acquisition and Data Analysismentioning
confidence: 99%
“…Eq. 2 shows the application of the modified Beer-Lambert law to single-wavelength PPG signals, assuming constant scattering [8].…”
Section: Signal Acquisition and Data Analysismentioning
confidence: 99%
“…Equation (9) is used to calculate the average depth of probing (Z r,λ ) for particular optical properties(μ a , μ s ') and source to detector separation (r). Equation (10) describes the probability distribution (P z,r ) of the depths reached by photons. …”
Section: Customization Of the Ppg Sensor Boardsmentioning
confidence: 99%
“…By analyzing the pulsatile and non-pulsatile components of the PPG signal, information about the perfusion and oxygenation of the tissue probed can be extracted [9,10]. Note that the pulsatile components stem from the arterial pulsations and the non-pulsatile components stem from the optical properties of the tissue, venous blood, and non-pulsatile arterial blood [9].…”
Section: Introductionmentioning
confidence: 99%
“…Measurement locations are usually extremities such as finger and earlobe, but several different locations such as the esophagus, splanchnic organs, and flaps have been investigated as well (Kyriacou 2006(Kyriacou , 2013. While the ac component of the signal is predominantly used to assess local arterial blood inflow, the dc component has been proved to provide information on venous blood, respiration, vasodilation/constriction, blood pressure, and perfusion (Shelley 2007, Reisner et al 2008, Walton et al 2010, Abay and Kyriacou 2015. However, the main application of PPG signals is the noninvasive estimation of arterial oxygen saturation (SpO 2 ).…”
Section: Introductionmentioning
confidence: 99%