2016
DOI: 10.1002/micr.30151
|View full text |Cite
|
Sign up to set email alerts
|

Refinements of nerve repair with connector‐assisted coaptation

Abstract: Peripheral nerve repair can be very rewarding for both surgeon and patient when expected outcomes are achieved. In many cases, however, the results are suboptimal due to number of possible objective and technical reasons. Although we cannot influence patent's comorbidities, the extent or mechanism of the nerve injury, we may help optimize technical details when aiming towards improved outcomes. While the suture coaptation for primary nerve repair or nerve reconstruction with grafting served as the reconstructi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 27 publications
(17 citation statements)
references
References 35 publications
(81 reference statements)
0
12
0
2
Order By: Relevance
“…33 For example, nerve allograft has been used to reconstruct nerves after resection of painful neuromas-in-continuity 33 and conduits, when placed over a nerve coaptation, have been shown to reduce the likelihood of pain at the coaptation by 50%. 34 However, although nerve caps have been utilized as a method to try and prevent neuroma development in the past, they were either made from nonbiologic materials such as silicone or from autologous tissues such as vein or epineurium. 12,21 These treatments have not gained in popularity, likely due to the fact that silicone can cause problematic reactions when implanted in the body and autologous tissue requires extra operative time, introduces risks with donor site morbidity, and can pose an additional technical challenge while not guaranteeing the containment of axons within the cap.…”
Section: Discussionmentioning
confidence: 99%
“…33 For example, nerve allograft has been used to reconstruct nerves after resection of painful neuromas-in-continuity 33 and conduits, when placed over a nerve coaptation, have been shown to reduce the likelihood of pain at the coaptation by 50%. 34 However, although nerve caps have been utilized as a method to try and prevent neuroma development in the past, they were either made from nonbiologic materials such as silicone or from autologous tissues such as vein or epineurium. 12,21 These treatments have not gained in popularity, likely due to the fact that silicone can cause problematic reactions when implanted in the body and autologous tissue requires extra operative time, introduces risks with donor site morbidity, and can pose an additional technical challenge while not guaranteeing the containment of axons within the cap.…”
Section: Discussionmentioning
confidence: 99%
“…When a tension-free coaptation is not possible, synthetic or biological conduits may be used [61] . In the field of peripheral nerve surgery, connector-assisted coaptations may decrease operative time, improve sensory outcomes, and decrease pain [62] . Multiple pharmacologic agents, such as Acetyl-L-carnitine, testosterone, and various growth factors have been investigated as a means to enhance nerve regeneration [63,64] .…”
Section: Mechanisms and Assessments Of Flap Reinnervationmentioning
confidence: 99%
“…Aunque los conductos pueden tener una indicación limitada en la reconstrucción para brecha nerviosa, varios estudios respaldan su uso como complementos de las reparaciones primarias y de las reconstrucciones de brecha mediante aloinjertos (18,21,26,27) . Funcionan como una barrera física entre el nervio reparado y el entorno externo, que protege y contiene las proteínas de la matriz extracelular necesarias para una curación óptima en el sitio de reparación, así como para prevenir el crecimiento excesivo y el escape axonal (28,29,30,31,32) . Wilson et al, realizaron un estudio comparando envolturas de conducto de colágeno de tipo I con envolturas de submucosa de intestino delgado porcino en reparaciones primarias de NL.…”
Section: Bibliografíaunclassified
“…Encontraron que no había diferencias en las tasas de RSF para ninguno de los grupos y que los 43 pacientes incluidos en el estudio tenían una puntuación igual o superior a S3 en la escala CIM (18) . Si bien el tamaño de la muestra del estudio no fue lo suficientemente grande como para demostrar diferencias estadísticamente significativas entre las reparaciones envueltas sin conector y las reparaciones envueltas con conector, creemos que este es un complemento útil para optimizar la recuperación sensitiva (28,29,33) .…”
Section: Bibliografíaunclassified