2003
DOI: 10.1120/1.1617191
|View full text |Cite
|
Sign up to set email alerts
|

Reference photon dosimetry data: A preliminary study of in-air off-axis factor, percentage depth dose, and output factor of the Siemens Primus linear accelerator

Abstract: The dosimetric characteristics for modern computer‐controlled linear accelerators with the same make, model, and nominal energy are known to be very similar, as long as the machines are unaltered from the manufacturer's original specifications. In this preliminary study, a quantitative investigation of the similarity in the basic photon dosimetry data from the Siemens Primus linear accelerators at eight different institutions is reported. The output factor, percentage depth dose (PDD), and in‐air off‐axis fact… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2004
2004
2016
2016

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…All the in-air OAFs reported in this study were measured with farmer-type ionization chambers, at a source-toaxis distance (SAD) of 100 cm, with an appropriate plastic buildup cap for the 6 MV photon beam. 2 RFS: the reference field size (RFS is normally a 10 ϫ 10 cm 2 field for photon beams. ); other variables are as defined earlier.…”
Section: Definitions Of Variables and Dosimetric Quantitiesmentioning
confidence: 99%
See 2 more Smart Citations
“…All the in-air OAFs reported in this study were measured with farmer-type ionization chambers, at a source-toaxis distance (SAD) of 100 cm, with an appropriate plastic buildup cap for the 6 MV photon beam. 2 RFS: the reference field size (RFS is normally a 10 ϫ 10 cm 2 field for photon beams. ); other variables are as defined earlier.…”
Section: Definitions Of Variables and Dosimetric Quantitiesmentioning
confidence: 99%
“…Details about the RPC's measurement techniques and instrumentation can be found elsewhere. 2 The RPC has accumulated a sufficient number of data on the Varian Clinac 2100 series linear accelerators and, therefore, a statistical analysis on the data could reveal some similarity among photon dosimetry data. The RPC-measured FDD, OF, and in-air OAF data were extracted from the RPC database for a statistical analysis.…”
Section: The Rpc-measured Datamentioning
confidence: 99%
See 1 more Smart Citation
“…(16) On the other hand, there are those who believe that, in the current age of computer design, linacs can be produce to very tight specifications and thus reference database are appropriate. (17,18) AAPM Task Group 106 cautions that careful evaluation is needed before using reference database in linacs' commissioning, but states that it is an excellent source of quality assurance for verifying commissioning results. (19) This was a recent point/counter point debate in the Medical Physics journal, where it was argued whether or not reference databases or vendor-provided databases are appropriate.…”
Section: Introductionmentioning
confidence: 99%
“…Because of the consistency in output performance of today's modern linac, the specific source models produced from this data are expected to be broadly applicable to Varian 2100 series linacs. 23,[25][26][27][28][29][30][31][32][33][34][35] Measurements were made using a small volume (0.04 cm 3 , 4 mm diameter) ion chamber. To account for the volume effects of the ion chamber, which tend to smear the dose and exaggerate the dose penumbra, a Gaussian convolution was applied to the calculated dose data for all profile comparisons.…”
Section: C Validation Testingmentioning
confidence: 99%