1984
DOI: 10.1016/0368-2048(84)80050-x
|View full text |Cite
|
Sign up to set email alerts
|

Reference energies for inner shell electron energy-loss spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
131
1

Year Published

1995
1995
2023
2023

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 248 publications
(135 citation statements)
references
References 16 publications
2
131
1
Order By: Relevance
“…They determined the energy of the 1s → 1π * transition at 530.8 eV with a stated accuracy of ±200 meV. By measuring the ion yield in a gas cell, Coreno and co-workers [34] improved the accuracy for this line to ±100 meV by normalization on the 1s → 1π * transition EELS measurements, both for O 2 [33] and CO [35], the latter being quoted to an accuracy of ±90 meV. To double-check this determination independently of the relatively low-resolution EELS measurements, we used a Scienta electron spectrometer installed on a second branch of the PLEIADES beam line.…”
Section: Excitation Source and Energy Calibrationmentioning
confidence: 99%
“…They determined the energy of the 1s → 1π * transition at 530.8 eV with a stated accuracy of ±200 meV. By measuring the ion yield in a gas cell, Coreno and co-workers [34] improved the accuracy for this line to ±100 meV by normalization on the 1s → 1π * transition EELS measurements, both for O 2 [33] and CO [35], the latter being quoted to an accuracy of ±90 meV. To double-check this determination independently of the relatively low-resolution EELS measurements, we used a Scienta electron spectrometer installed on a second branch of the PLEIADES beam line.…”
Section: Excitation Source and Energy Calibrationmentioning
confidence: 99%
“…The C 1s and O 1s spectra were calibrated using the C 1s f π* transition of CO (287.40 eV) 23 and the O 1s f π* transition of CO (534.20 eV). 24 The Si 2p/2s spectra were calibrated with respect to the C 1s spectra of each species.…”
Section: Iseels Measurementsmentioning
confidence: 99%
“…To find precise energy positions for the mentioned structures, we routinely measure and calibrate them against well defined ionization lines of N 2 in all available orders up to the fifth. The energy position for the first peak of the N 2 1s vibrational structure is at 400.77 eV (Sodhi & Brion, 1984). The reference energies, their energetic positions and accuracy for all available structures are summarized in Fig.…”
Section: Optics Beamlinementioning
confidence: 99%