Reference data sets for validating GSHP system models and analyzing performance parameters based on a five-year operation period

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0
3

Year Published

2015
2015
2019
2019

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(17 citation statements)
references
References 17 publications
0
14
0
3
Order By: Relevance
“…However, the phreatic level is 3.5 m. So, in practice, it is expected that the surrounding soil is saturated, which would turn into higher values of the conductivity and volumetric heat capacity, as it was pointed out in [29] and [38]. Measurements of the ground undisturbed temperature were undertaken at the Geocool plant and the registered values (around 19.5 o C) were very close to the water temperature coming from the ground loop, which is around 20 o C as presented in [35] and [36]. Finally, as it can be observed in Figure 6, water temperature is measured at the inlet and outlet of each one of the six boreholes connected in parallel.…”
Section: Ground Source Heat Exchangermentioning
confidence: 68%
See 2 more Smart Citations
“…However, the phreatic level is 3.5 m. So, in practice, it is expected that the surrounding soil is saturated, which would turn into higher values of the conductivity and volumetric heat capacity, as it was pointed out in [29] and [38]. Measurements of the ground undisturbed temperature were undertaken at the Geocool plant and the registered values (around 19.5 o C) were very close to the water temperature coming from the ground loop, which is around 20 o C as presented in [35] and [36]. Finally, as it can be observed in Figure 6, water temperature is measured at the inlet and outlet of each one of the six boreholes connected in parallel.…”
Section: Ground Source Heat Exchangermentioning
confidence: 68%
“…The overall system operation is controlled by a timer which is programmed to operate between 7am and 9pm, 5 days per week, as the system is switched off during the weekends. Further information of the installation description can be found in [35] and [36].…”
Section: Geocool Plantmentioning
confidence: 99%
See 1 more Smart Citation
“…The system is fully monitored by a sensor network, and the data have been collected by a data acquisition unit since February 2005. The experimental data have been deeply analyzed in [32,33]. It should be noted that, in May 2011, in the framework of another FP7 European project called Ground-Med [31], the former heat pump was replaced with a new one consisting of two compressors of the same capacity in tandem, working with R410A.…”
Section: Gshp Systemmentioning
confidence: 99%
“…), mass flow rates (Danfoss flow meter model massflo MASS 6000 with accuracy <0.1%) and power consumptions (Gossen Metrawatt power meter model A2000 with accuracy ± 0.5%). A more detailed description of the system can be found in previous publications (Ruiz-Calvo and Montagud 2014;Cervera-Vázquez, et al 2015a). …”
Section: Geothermal Experimental Plantmentioning
confidence: 99%