2009 International Conference on Advances in Computational Tools for Engineering Applications 2009
DOI: 10.1109/actea.2009.5227885
|View full text |Cite
|
Sign up to set email alerts
|

Reduction of power field radiation for PLC applications

Abstract: In this article, we present our investigations on the radiation of the power-line communication (PLC) system. Power line communication or power line carrier is a technology for carrying data on a conductor usually dedicated to electric power transmission. At high frequency, the power lines, whose are dimensioned and adjusted for electrical energy transfer, not to carry high frequency (HF) data signal, act then as radiating antennas.The system has a number of issues. The primary one is that power lines are inhe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
3
0
1

Year Published

2014
2014
2016
2016

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 3 publications
0
3
0
1
Order By: Relevance
“…En un enfoque teórico, Chaaban (2009) analizan una antena de hilo y representan el campo radiado en función de la reducción de la longitud y el radio del conductor de la antena, para demostrar que la potencia radiada es mínima para diferentes valores de longitud. A partir de este resultado se pueden escoger valores de frecuencia óptimos para limitar la potencia electromagnética radiada y, así, reducirla a alrededor de 7.5 dB.…”
Section: Estado Del Arte En Técnicas De Reducción De Interferencia Deunclassified
“…En un enfoque teórico, Chaaban (2009) analizan una antena de hilo y representan el campo radiado en función de la reducción de la longitud y el radio del conductor de la antena, para demostrar que la potencia radiada es mínima para diferentes valores de longitud. A partir de este resultado se pueden escoger valores de frecuencia óptimos para limitar la potencia electromagnética radiada y, así, reducirla a alrededor de 7.5 dB.…”
Section: Estado Del Arte En Técnicas De Reducción De Interferencia Deunclassified
“…[22]. There has been a lot of theoretical modeling for radiated emissions from PLC systems [23][24][25][26][27][28][29]. Several methods have been used to compute the EM field such as the four-port network method [29], the MoM [28] and the so-called wire grid model [27].…”
Section: Introductionmentioning
confidence: 99%
“…The radiation level for the band 95 kHz to 148.5 kHz is limited to 116 dBμV for general use and for particular applications such as industrial areas which is limited to 134 dBμV. The frequency range [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15] MHz is limited to 30μV/m and 15-80 MHz to 100 μV/m [1] and [2].…”
Section: Introductionmentioning
confidence: 99%
“…From the previous works on the factor accelerating BPLC radiation, different views have been presented, [9], identifies the presence of common mode (CM) current in the network as a source of BPLC signal radiation, while [10] suggests that any discontinuity, interconnection or bent in powerline network can stand as potential source of BPLC radiation. The authors in [11] have considered BPLC as an antenna radiating when subjected to high frequency signals, describing bent or discontinuity/joints responsible to change high frequency current into EM, and vice versa. Also, [12] suggests that mismatch of impedances causes reflection and retransmission of signal in the network which mount on the signal to radiate with emission which is above the EMC recommended limit.…”
Section: Introductionmentioning