2018
DOI: 10.1016/j.arth.2017.11.052
|View full text |Cite
|
Sign up to set email alerts
|

Reduction of Particles in the Operating Room Using Ultraviolet Air Disinfection and Recirculation Units

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
33
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 33 publications
(34 citation statements)
references
References 30 publications
1
33
0
Order By: Relevance
“…The C‐UVC unit was placed in the OR, 2 m from the surgical table and 8 m from the door to the substerile corridor (i.e., source of air contamination). A previous study has shown an arrangement with the C‐UVC unit 4–8 m from the substerile corridor to be effective at reducing particle counts in a controlled OR setting . Air enters at the bottom of the unit, passes through the filter where airborne microogranisms are exposed to C‐UVC, and then flows out through the clean air exhaust at the top of the unit (Fig.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The C‐UVC unit was placed in the OR, 2 m from the surgical table and 8 m from the door to the substerile corridor (i.e., source of air contamination). A previous study has shown an arrangement with the C‐UVC unit 4–8 m from the substerile corridor to be effective at reducing particle counts in a controlled OR setting . Air enters at the bottom of the unit, passes through the filter where airborne microogranisms are exposed to C‐UVC, and then flows out through the clean air exhaust at the top of the unit (Fig.…”
Section: Methodsmentioning
confidence: 99%
“…C‐UVC disinfection and recirculation units have previously shown to reduce particle counts in a strictly controlled OR setting; however, its efficacy in doing so in a dynamic operating environment has not been assessed. Furthermore, the ability of C‐UVC filtration to reduce airborne bacteria has not been assessed with traditional bacterial plating methods.…”
mentioning
confidence: 99%
“…The device runs continuously during a procedure without an operator present and does not create any air turbulence or disruption of the OR air balance …”
Section: Adjunctive or Air Cleaning Technologymentioning
confidence: 99%
“…Several conference reports and one laboratory pilot study have described the efficacy and benefits of OR air cleaning technology using HEPA filtration plus UV‐C disinfection. At the 2017 Australasian College for Infection Prevention and Control annual conference, Walsh reported that air filtration and disinfection units that combine HEPA filtration and UV‐C disinfection technologies significantly reduced the total and viable particle counts in a highly controlled OR setting.…”
Section: Adjunctive or Air Cleaning Technologymentioning
confidence: 99%
See 1 more Smart Citation