1981
DOI: 10.1021/ac00231a011
|View full text |Cite
|
Sign up to set email alerts
|

Reduction of matrix ionization interference in laser-enhanced ionization spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
49
0

Year Published

1984
1984
2001
2001

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 83 publications
(49 citation statements)
references
References 10 publications
0
49
0
Order By: Relevance
“…The LEI spectrometer utilizes a water-cooled cathode imm ersed in the¯ame atom izer. 9 The laser excitation system ( Fig. 1) consists of either a single dye laser (S canM ate 1, L am bd a P hy sik, F t. L au derdale, F L ) pumped by the third harm onic (355 nm) of a Nd:YAG (Surelite II-10, Continuum, Santa Clara, CA) operating at 10 Hz, or two dye lasers (ScanMate 2 and FL 3001, Lambda Physik) pumped by a XeF excimer laser at 351 nm (L PX 210i, Lambda Physik) operating at 30 Hz.…”
Section: Exp Erim Entalmentioning
confidence: 99%
“…The LEI spectrometer utilizes a water-cooled cathode imm ersed in the¯ame atom izer. 9 The laser excitation system ( Fig. 1) consists of either a single dye laser (S canM ate 1, L am bd a P hy sik, F t. L au derdale, F L ) pumped by the third harm onic (355 nm) of a Nd:YAG (Surelite II-10, Continuum, Santa Clara, CA) operating at 10 Hz, or two dye lasers (ScanMate 2 and FL 3001, Lambda Physik) pumped by a XeF excimer laser at 351 nm (L PX 210i, Lambda Physik) operating at 30 Hz.…”
Section: Exp Erim Entalmentioning
confidence: 99%
“…Flame Burner. The experimental apparatus of a twostep LEI has been illustrated previously, 11,15,16,26 so only a brief description is given below. We performed the LEI experiment, as shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The resulting LEI ions were collected with a water-cooled cylinder probe along the ¯ame, biased at 2 1000 V and suspended 1.5± 2.0 cm above the burner head. 16 In an effort to avoid interference from ¯ame components, the electrode was positioned slightly outside the ¯ame, about 4± 6 mm off the axis of the burner slot. The ion enhancement in this work proved to be comparable to that obtained with the electrode inside the ¯ame.…”
Section: Methodsmentioning
confidence: 99%
“…A wa ter-cooled cyl in der probe along the flame axis was bi ased at -1000 V and sus pended 2 cm above the burn head. 30 The burner served as the other elec trode, from which the LEI cur rent sig nal was col lected and am pli fied with a cur rent-tovoltage con verter (Keithley, Model 428), and then fed into a tran sient dig i tizer (LeCory 9450A). The LEI wave form was av er aged over 200 pulses and trans ferred to a PC through a GPIB in ter face board.…”
Section: Lei De Tec Tionmentioning
confidence: 99%