2019
DOI: 10.3390/en12224319
|View full text |Cite
|
Sign up to set email alerts
|

Reduction of DC Current Ripples by Virtual Space Vector Modulation for Three-Phase AC–DC Matrix Converters

Abstract: In this paper, the virtual space vector modulation for the AC–DC (alternating current–direct current) matrix converters is proposed to reduce the DC current ripples in the whole modulation index range. In the proposed method, each virtual vector is synthesized by the two nearest original active vectors. To synthesize the current reference vector, two virtual vectors and one zero vector are used in every switching period. The main principle of the proposed method is to reduce the dwelling period of the largest … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 27 publications
(46 reference statements)
0
3
0
Order By: Relevance
“…To ensure precise control, we harnessed the power of space vector modulation (SVPWM) throughout our research. By meticulously manipulating the state of the individual six switching devices within the inverters, authors emulated the sinusoidal waveforms characteristic of the AC network with remarkable fidelity [31]. This fine-grained control allowed us to adjust both frequency and amplitude parameters with exquisite precision, guaranteeing robust and accurate experimental conditions.…”
Section: Arc Failure Specifications and Characteristicsmentioning
confidence: 99%
See 1 more Smart Citation
“…To ensure precise control, we harnessed the power of space vector modulation (SVPWM) throughout our research. By meticulously manipulating the state of the individual six switching devices within the inverters, authors emulated the sinusoidal waveforms characteristic of the AC network with remarkable fidelity [31]. This fine-grained control allowed us to adjust both frequency and amplitude parameters with exquisite precision, guaranteeing robust and accurate experimental conditions.…”
Section: Arc Failure Specifications and Characteristicsmentioning
confidence: 99%
“…characteristic of the AC network with remarkable fidelity [31]. This fine-graine allowed us to adjust both frequency and amplitude parameters with exquisite guaranteeing robust and accurate experimental conditions.…”
Section: Arc Failure Specifications and Characteristicsmentioning
confidence: 99%
“…As can be seen in Figure 10 and Table 4, unlike the current doubler CSR in [16] and matrix-type CSR in [17], a standard six-switch CSR has six transistors and six diodes, as well as the proposed one. Although a three-switch CSR is designed in [18], the converter has the maximum number of diodes and the conduction loss is high.…”
Section: Comparative Analysis Of Other Conventional Csrsmentioning
confidence: 99%
“…There are several three-phase CSRs introduced in most of the literature, including the six-switch CSR [14], three-phase four-wire CSR [15], current doubler CSR [16], matrix-type CSR [17], three-switch CSR [18], swiss-type CSR [19], delta-type CSR [20], split freewheeling diode CSR [21], etc. Another kind of isolated CSR is achieved with a high-frequency transformer [22][23][24][25][26][27].…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, scholars also utilize different filters to suppress the grid-side current harmonics of MC, such as parallel active filter, hybrid filter, etc. [17][18][19][20][21][22][23].…”
Section: Introductionmentioning
confidence: 99%