2022
DOI: 10.1016/j.joms.2022.03.004
|View full text |Cite
|
Sign up to set email alerts
|

Reduction of CT Artifacts Using Polyetheretherketone (PEEK), Polyetherketoneketone (PEKK), Polyphenylsulfone (PPSU), and Polyethylene (PE) Reconstruction Plates in Oral Oncology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
24
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(26 citation statements)
references
References 42 publications
(33 reference statements)
2
24
0
Order By: Relevance
“…In the wake of scientific efforts to counter these problems, polymer materials are increasingly being investigated as possible substitutes. Just recently it was shown that the polymer materials PEEK, PEKK, PPSU, and PE cause significantly fewer artifacts in CT imaging when used as mandible reconstruction plates compared to titanium tested on human cadavers [ 5 ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In the wake of scientific efforts to counter these problems, polymer materials are increasingly being investigated as possible substitutes. Just recently it was shown that the polymer materials PEEK, PEKK, PPSU, and PE cause significantly fewer artifacts in CT imaging when used as mandible reconstruction plates compared to titanium tested on human cadavers [ 5 ].…”
Section: Discussionmentioning
confidence: 99%
“…Due to sophisticated fitting accuracy, the use of PSI in mandibular reconstruction is widely accepted [ 4 ]. However, titanium plates cause significant streak and blooming artifacts in computer tomography (CT) images thwarting thorough radiological assessment of implant surrounding tissues [ 5 ]. This phenomenon disadvantageously affects postoperative radiological tumor follow-up as well as adjuvant radiotherapy strongly dependent on a high-resolution, artifact-free planning CT [ 6 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, the RFID ports in this study uses a plastic material, polyetheretherketone (PEEK), as the needle guide, which differs from the stainless steel in conventional TEs. As PEEK has a relatively lower HU than other metals, this potentially reduces the artifacts on CT imaging [20].…”
Section: Discussionmentioning
confidence: 99%
“…The advantages of PSI-based orthognathic surgery are well described, and the procedure has been proven for many years [ 20 , 21 , 22 , 23 ]. Furthermore, augmentative procedures have been established in which PEEK bone implants can be used to adequately replace bone defects or malpositions [ 24 , 25 , 26 , 27 , 28 , 29 ]. In recent years, the great benefit of PEEK bone augmentations for the treatment of facial asymmetries has been discovered.…”
Section: Introductionmentioning
confidence: 99%